Summary of Study ST003098

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001923. The data can be accessed directly via it's Project DOI: 10.21228/M85149 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003098
Study TitleLactiplantibacillus plantarum intervention on cecum tryptophans of gestational fecal microbiome transplant germ-free mice
Study SummaryThe study aims to investigate whether administration of probiotic L. plantarum could influence profiling of cecum tryptophans of germ-free mice. L. plantarum intervention during gestation of humanized GF mice showed no significant difference on tryptophans’s content.
Institute
Beijing Sanyuan Foods Co. Ltd
Last NameLijun
First NameChen
Address8th yingchang street, yinghai district
Emailchenlijun@sanyuan.com.cn
Phone01056306594
Submit Date2024-02-18
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2024-03-08
Release Version1
Chen Lijun Chen Lijun
https://dx.doi.org/10.21228/M85149
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005069
Analysis type MS
Chromatography type LC
Chromatography system Thermo Vanquish
Column Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um)
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name ABI Sciex 5000
Ion Mode POSITIVE
Units μg/g

MS:

MS ID:MS004807
Analysis ID:AN005069
Instrument Name:ABI Sciex 5000
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Ion Source Temperature 500°C, Ion Source Voltage 5500 V, Collision Gas 6 psi, Curtain Gas 30 psi, Atomizing Gas and Auxiliary Gas both 50 psi. 45 arbitrary units (AU), 13 AU, 1 AU, 350 °C, and 350 °C for sheath gas, aux gas, sweep gas, ion transfer tube, and vaporizer temperature, respectively. The ion source was operated using heated ESI with an ion spray voltage set at 5500 V in positive ion mode. Polarity switching and scheduled selected reaction monitoring (SRM) were employed.The raw data were firstly converted to mzXML format by MSConvert in the ProteoWizard software package (v3.0.8789) (Adusumilli et al., 2017) and processed using XCMS (Domingo-Almenara et al., 2020) for feature detection, retention time correction and alignment.
Ion Mode:POSITIVE
  logo