Summary of Study ST003124

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001942. The data can be accessed directly via it's Project DOI: 10.21228/M8PX4X This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003124
Study TitleSerum metabolites in inherited retinal degenerations
Study SummaryThe diagnosis of inherited retinal degeneration (IRD) is challenging owing to its phenotypic and genotypic complexity. Clinical information is important before a genetic diagnosis is made. Metabolomics studies the entire picture of bioproducts, which are determined using genetic codes and biological reactions. We demonstrated that the common diagnoses of IRD, including retinitis pigmentosa (RP), cone-rod dystrophy (CRD), Stargardt disease (STGD), and Bietti’s crystalline dystrophy (BCD), could be differentiated based on their metabolite heatmaps. Hundreds of metabolites were identified in the volcano plot compared with that of the control group in every IRD except BCD, considered as potential diagnosing markers. The phenotypes of CRD and STGD overlapped but could be differentiated by their metabolomic features with the assistance of a machine learning model with 100% accuracy. Moreover, EYS-, USH2A-associated, and other RP, sharing considerable similar characteristics in clinical findings, could also be diagnosed using the machine learning model with 85.7% accuracy. Further study would be needed to validate the results in the external dataset. By incorporating mass spectrometry and machine learning, a metabolomics-based diagnostic workflow for the clinical and molecular diagnoses of IRD was proposed in our study.
Institute
National Taiwan University
DepartmentDepartment of Chemistry
LaboratoryCheng-Chih Hsu's lab
Last NameChung
First NameHsin-Hsiang
AddressNo. 1, Sec. 4, Roosevelt Rd.
Emailhhchung@ntu.edu.tw
Phone+886-2-3366-1681
Submit Date2024-03-11
Total Subjects155
Num Males90
Num Females65
Raw Data AvailableYes
Raw Data File Type(s)mzXML
Analysis Type DetailLC-MS
Release Date2024-03-17
Release Version1
Hsin-Hsiang Chung Hsin-Hsiang Chung
https://dx.doi.org/10.21228/M8PX4X
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005119 AN005120 AN005121 AN005122
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters ACQUITY UPLC CSH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC CSH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Peak area Peak area Peak area Peak area

MS:

MS ID:MS004855
Analysis ID:AN005119
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS data were processed using Thermo Scientific Compound Discoverer v3.2 software.
Ion Mode:POSITIVE
Capillary Temperature:280℃
Ion Source Temperature:180℃
Ion Spray Voltage:3.5 kV
  
MS ID:MS004856
Analysis ID:AN005120
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS data were processed using Thermo Scientific Compound Discoverer v3.2 software.
Ion Mode:NEGATIVE
Capillary Temperature:280℃
Ion Source Temperature:180℃
Ion Spray Voltage:-3.5 kV
  
MS ID:MS004857
Analysis ID:AN005121
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS data were processed using Thermo Scientific Compound Discoverer v3.2 software.
Ion Mode:POSITIVE
Capillary Temperature:280℃
Ion Source Temperature:180℃
Ion Spray Voltage:3.5 kV
  
MS ID:MS004858
Analysis ID:AN005122
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS data were processed using Thermo Scientific Compound Discoverer v3.2 software.
Ion Mode:NEGATIVE
Capillary Temperature:280℃
Ion Source Temperature:180℃
Ion Spray Voltage:-3.5 kV