Summary of Study ST001761
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001127. The data can be accessed directly via it's Project DOI: 10.21228/M81D6M This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001761 |
Study Title | Application of the redox metabolite detection method for mouse biofluids |
Study Summary | This study was aimed at optimizing redox metabolites detection from mammalian biofluids. Three different extraction conditions were compared, including derivatization of glutathione. This study was with mouse cerebrospinal fluid. |
Institute | Boston Children's Hospital, Harvard Medical School |
Department | Pathology |
Laboratory | Naama Kanarek |
Last Name | Petrova |
First Name | Boryana |
Address | 300 Longwood Av, Boston, MA, 2115, USA |
boryana.petrova@childrens.harvard.edu | |
Phone | 6173557433 |
Submit Date | 2021-04-21 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2021-05-17 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Sample Preparation:
Sampleprep ID: | SP001844 |
Sampleprep Summary: | CSF was collected by puncture of the cisterna magna with a glass capillary [39] and flash-frozen for further analysis. Per condition, 3 µl of precleared CSF were extracted by brief sonication in 200 µl of the indicated extraction buffers. After centrifugation for 10 min at maximum speed on a benchtop centrifuge (Eppendorf) the cleared supernatant was dried using a nitrogen dryer and reconstituted in 30 µl water by brief sonication. Extracted metabolites were spun again and cleared supernatant was transferred to LC-MS micro vials. A small amount of each sample was pooled and serially diluted 3- and 10-fold to be used as quality controls throughout the run of each batch. Extraction buffer “A”: 40:40:20 of acetonitrile:methanol:water, supplemented with 0.1M formic acid and isotopically-labeled internal standards (17 amino acids and reduced glutathione, Cambridge Isotope Laboratories, MSK-A2-1.2 and CNLM-6245-10). Extraction buffer “B”: 80% LC-MS-grade methanol, 20% 25 mM Ammonium Acetate and 2.5 mM Na-Ascorbate prepared in LC-MS water and supplemented with isotopically labeled internal standards (17 amino acids and isotopically labelled reduced glutathione, Cambridge Isotope Laboratories, MSK-A2-1.2 and CNLM-6245-10). Extraction buffer “C” and “C + Ellman’s”: Solution 1: 100% LC-MS Methanol Solution 2: 25mM Ammonium Acetate and 2.5mM Na-Ascorbate in LC-MS water supplemented with isotopically labelled reduced glutathione and isotopically labeled internal standards (17 amino acids and reduced glutathione, Cambridge Isotope Laboratories, MSK-A2-1.2 and CNLM-6245-10). Ellman’s reagent (5,5′-Dithiobis(2-nitrobenzoic acid),D8130, Sigma Aldrich): 20 mM in “Solution 2”. Final composition is 80% solution 1 and 20% solution 2. |