Summary of Study ST003074

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001914. The data can be accessed directly via it's Project DOI: 10.21228/M89T5V This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003074
Study TitleSpectral information for 3,5,3’-L-triiodothyronine (T3) and 3,5,3’5’-L-tetraiodothyronine (T4) from synthetic standards
Study SummaryWe utilized synthetic standards for 3,5,3’-L-triiodothyronine (T3) and 3,5,3’5’-L-tetraiodothyronine (T4) to obtain high-quality MS2-level information that would aid compound identification from biological matrixes
Institute
Boston Childrens Hospital
DepartmentPatholody
LaboratoryKanarek Lab
Last NamePetrova
First NameBoryana
Address300 Longwood Av
Emailboryana.petrova@childrens.harvard.edu
Phone6173557433
Submit Date2024-01-11
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-02-14
Release Version1
Boryana Petrova Boryana Petrova
https://dx.doi.org/10.21228/M89T5V
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Project:

Project ID:PR001914
Project DOI:doi: 10.21228/M89T5V
Project Title:Optimized Mass Spectrometry Detection of Thyroid Hormones and Polar Metabolites in Rodent Cerebrospinal Fluid
Project Summary:Thyroid hormones (TH) are required for brain development and function. Cerebrospinal fluid (CSF), which bathes the brain and spinal cord, contains TH as free hormone, or as bound to transthyretin (TTR). Tight TH level regulation in the central nervous system is essential for de-velopmental gene expression that governs neurogenesis, myelination, and synaptogenesis. This integrated function of TH highlights the importance of developing precise and reliable methods for assessing TH levels in CSF. We report an optimized liquid chromatography-mass spectrome-try (LC-MS) based method to measure TH in rodent CSF and serum, applicable to both fresh and frozen samples. Using this new method, we find distinct differences in CSF TH in pregnant dams vs. non-pregnant adults and in embryonic vs. adult CSF. Further, targeted LC-MS metabolic pro-filing uncovers distinct central carbon metabolism in the CSF of these populations. TH detection and metabolite profiling of related metabolic pathways open new avenues of rigorous research into CSF TH and will inform future studies on metabolic alterations in CSF during normal de-velopment.
Institute:Boston Childrens Hospital
Department:Pathology
Laboratory:Kanarek Lab
Last Name:Petrova
First Name:Boryana
Address:300 Longwood Av
Email:boryana.petrova@childrens.harvard.edu
Phone:6173557433

Subject:

Subject ID:SU003189
Subject Type:Synthetic sample

Factors:

Subject type: Synthetic sample; Subject species: - (Factor headings shown in green)

mb_sample_id local_sample_id Standard
SA332321T4_62nM 3,5,3’5’-L-tetraiodothyronine
SA332320T3_62nM 3,5,3’-L-triiodothyronine
Showing results 1 to 2 of 2

Collection:

Collection ID:CO003182
Collection Summary:The presented study is on chemical standards
Sample Type:synthetic

Treatment:

Treatment ID:TR003198
Treatment Summary:no treatments were performed

Sample Preparation:

Sampleprep ID:SP003195
Sampleprep Summary:standards were solubilized in 50/50 methanol/water with 10uM ammonium hydroxide

Combined analysis:

Analysis ID AN005032
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Merck Supelco Ascentis Express C18 (150 x 2.1mm,2.7um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units NA

Chromatography:

Chromatography ID:CH003803
Methods Filename:C18_LC_Conditions.pdf
Instrument Name:Thermo Vanquish
Column Name:Merck Supelco Ascentis Express C18 (150 x 2.1mm,2.7um)
Column Temperature:30
Flow Gradient:0–5 min: gradient was held at 5% B; 2–12.1 min: linear gradient of 5% to 95% B; 12.1–17.0 min: 95% B; 17.1–21.0 min: gradient was returned to 5% B
Flow Rate:0.25 ml/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:Reversed phase

MS:

MS ID:MS004771
Analysis ID:AN005032
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS data acquisition was performed using a Q Exactive Orbitrap benchtop orbitrap mass spectrometer equipped with an Ion Max source and a HESI II probe (Thermo Fisher Scientific, San Jose, CA, USA)in positive ionization mode and a PRM acquisition with the resolution set at 17,500, the AGC target at 2 × 10^5, and the maximum injection time (Max IT) at 40 msec. Collision energies were set at 20,40,60 and 80 NCE. Inclusion list was 651.7973 m/z for T3 and 777.6940 m/z for T4. HESI conditions were as follows: sheath gas flow rate: 40 units; Aug gas flow rate: 10 units; sweet gas flow rate: 0; spray voltage: 3.5 kV (pos), 2.8 kV (neg); capillary temperature: 380 °C; S-lens RF: 60; Aux gas heater temperature: 420 °C. MS spectra were consolidated using the mzVault software, automatically thresholded for noise and recalibrated for mass error.
Ion Mode:POSITIVE
  logo