Return to study ST000221 main page

MB Sample ID: SA010739

Local Sample ID:BM049411SC003
Subject ID:SU000240
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000240
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
BM049411SC003SA010739FL002565slow MMCognitive Status

Collection:

Collection ID:CO000228
Collection Summary:Bone marrow cells were collected after fasting. Collected cells were CD138 sorted and frozen in -80C until analysis.
Sample Type:Bone marrow cells
Collection Location:Illiac crest

Treatment:

Treatment ID:TR000248

Sample Preparation:

Sampleprep ID:SP000242
Sampleprep Summary:1) Incubated cell pellets on ice for 15 min
2) Added PBS to cells and vortex well
3) Sonicate for 1 min in ice bath
4) Added MeOH+ACN mixture to cells and vortex well
5) Sonicated for 1 min in ice bath
6) Incubated on ice for 30 min + spin for 20 min at 18K RPM
7) Combined 110 ul from each sample into a pool sample (330 ul total)
8) Split pool into two fractions of 150 ul each (hilic & C18)
9) Split remaning sample into 150 ul x 2 (hilic & C18)

Combined analysis:

Analysis ID AN000327 AN000328 AN000329 AN000330
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters high-strength silica (150 x 2.1mm,1.8um) Waters high-strength silica (150 x 2.1mm,1.8um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type TOF TOF TOF TOF
MS instrument name Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Peak area Peak area Peak area Peak area

Chromatography:

Chromatography ID:CH000246
Chromatography Summary:C18
Chromatography Comments:Metabolite separation was achieved using an Acquity UPLC system (Waters, Milford, MA) with both hydrophilic interaction chromatography (HILIC) (ethylene-bridged hybrid 2.1150 mm, 1.7 mm; Waters) and reversed-phase liquid chromatography C18 (RPLC) (high-strength silica 2.1150 mm, 1.8 m; Waters). For each column, the run time was 20 min at a flow rate of 400 L/min. Reverse-phase chromatography was performed using 99% solvent A (5 mmol/L NH4 acetate, 0.1% formic acid, and 1% acetonitrile) to 100% solvent B (95% acetonitrile with 0.1% formic acid). The gradient was 0 min, 0% B; 1 min, 0% B; 3 min, 5% B; 13.0 min, 100% B; 16 min, 100% B; 16.5 min, 0% B; and 20 min, 0% B. The hydrophilic interaction chromatography gradient was as follows: 0 min, 100% B; 1 min, 100% B; 5 min, 90% B; 13.0 min, 0% B; 16 min, 0% B; 16.5 min, 100% B; and 20 min, 100% B. The injection volume of each sample was 5 L and column was maintained at 50C.
Instrument Name:Waters Acquity
Column Name:Waters high-strength silica (150 x 2.1mm,1.8um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH000247
Chromatography Summary:HILIC
Chromatography Comments:Metabolite separation was achieved using an Acquity UPLC system (Waters, Milford, MA) with both hydrophilic interaction chromatography (HILIC) (ethylene-bridged hybrid 2.1150 mm, 1.7 mm; Waters) and reversed-phase liquid chromatography C18 (RPLC) (high-strength silica 2.1150 mm, 1.8 m; Waters). For each column, the run time was 20 min at a flow rate of 400 L/min. Reverse-phase chromatography was performed using 99% solvent A (5 mmol/L NH4 acetate, 0.1% formic acid, and 1% acetonitrile) to 100% solvent B (95% acetonitrile with 0.1% formic acid). The gradient was 0 min, 0% B; 1 min, 0% B; 3 min, 5% B; 13.0 min, 100% B; 16 min, 100% B; 16.5 min, 0% B; and 20 min, 0% B. The hydrophilic interaction chromatography gradient was as follows: 0 min, 100% B; 1 min, 100% B; 5 min, 90% B; 13.0 min, 0% B; 16 min, 0% B; 16.5 min, 100% B; and 20 min, 100% B. The injection volume of each sample was 5 L and column was maintained at 50C.
Instrument Name:Waters Acquity
Column Name:Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um)
Chromatography Type:HILIC

MS:

MS ID:MS000276
Analysis ID:AN000327
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:C18-PESI (+ve ESI) A 6220 ToF-MS (Agilent Technologies) was operated in both positive and negative electrospray ionization (ESI) modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were 5 parts per million (ppm) and 20,000 ppm, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:POSITIVE
  
MS ID:MS000277
Analysis ID:AN000328
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:C18-NESI (-ve ESI) A 6220 ToF-MS (Agilent Technologies) was operated in both positive and negative electrospray ionization (ESI) modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were 5 parts per million (ppm) and 20,000 ppm, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:NEGATIVE
  
MS ID:MS000278
Analysis ID:AN000329
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:HILIC-PESI (+ve ESI) A 6220 ToF-MS (Agilent Technologies) was operated in both positive and negative electrospray ionization (ESI) modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were 5 parts per million (ppm) and 20,000 ppm, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:POSITIVE
  
MS ID:MS000279
Analysis ID:AN000330
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:HILIC-PESI (-ve ESI) A 6220 ToF-MS (Agilent Technologies) was operated in both positive and negative electrospray ionization (ESI) modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were 5 parts per million (ppm) and 20,000 ppm, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:NEGATIVE
  logo