Return to study ST000350 main page
MB Sample ID: SA015368
Local Sample ID: | 7 |
Subject ID: | SU000370 |
Subject Type: | Animal |
Subject Species: | Rattus norvegicus |
Taxonomy ID: | 10116 |
Species Group: | Mammal |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU000370 |
Subject Type: | Animal |
Subject Species: | Rattus norvegicus |
Taxonomy ID: | 10116 |
Species Group: | Mammal |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
7 | SA015368 | FL003406 | HIP | Genotype |
Collection:
Collection ID: | CO000364 |
Collection Summary: | Plasma was collected then flash frozen in a liquid nitrogen cooled biopress |
Sample Type: | Blood |
Treatment:
Treatment ID: | TR000384 |
Treatment Summary: | - |
Sample Preparation:
Sampleprep ID: | SP000377 |
Sampleprep Summary: | The samples were crash deprotonized by methanol precipitation and spiked with D27-deuterated myristic acid (D27-C14:0) as an internal standard for retention-time locking and dried. The trimethylsilyl-D27-C14:0 standard retention time (RT) was set at 16.727 min. Reactive carbonyls were stabilized at 50C with methoxyamine hydrochloride in dry pyridine. Metabolites were made volatile with TMS groups using N-methyl-N-(trimethylsilyl) trifluoroacetamide or MSTFA with catalytic trimethylchlorosilane at 50C. |
Combined analysis:
Analysis ID | AN000566 |
---|---|
Analysis type | MS |
Chromatography type | GC |
Chromatography system | Agilent 6890N |
Column | Agilent DB5-MS (15m x 0.25mm,0.25um) |
MS Type | EI |
MS instrument type | Single quadrupole |
MS instrument name | Agilent 5975 |
Ion Mode | POSITIVE |
Units | Peak values (Log transformed) |
Chromatography:
Chromatography ID: | CH000403 |
Chromatography Summary: | GC/MS methods follow previous studies using a 6890 N GC connected to a 5975 Inert single quadrupole MS (Agilent Technologies, Santa Clara, CA) (Bonikos et al. 1975; Fiehn 2008; Kind et al. 2009). The two wall-coated, open-tubular GC columns connected in series are both from J&W/Agilent (part 122–5512), DB5-MS, 15 meters in length, 0.25 mm in diameter, with an 0.25-l m luminal film. Positive ions generated with conventional electron-ionization at 70 eV are scanned broadly from 600 to 50 m/z in the detector throughout the 45 min cycle time. |
Instrument Name: | Agilent 6890N |
Column Name: | Agilent DB5-MS (15m x 0.25mm,0.25um) |
Chromatography Type: | GC |
MS:
MS ID: | MS000502 |
Analysis ID: | AN000566 |
Instrument Name: | Agilent 5975 |
Instrument Type: | Single quadrupole |
MS Type: | EI |
Ion Mode: | POSITIVE |