Return to study ST001286 main page
MB Sample ID: SA093605
Local Sample ID: | bovine_CL_LD_replicate3 |
Subject ID: | SU001358 |
Subject Type: | Mammal |
Subject Species: | Bos taurus |
Taxonomy ID: | 9913 |
Gender: | Female |
Animal Animal Supplier: | JBS Beef Plant 3435 Edward Babe Gomez Ave, Omaha, NE 68107 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002130 | AN002131 | AN002132 | AN002133 | AN002134 | AN002135 | AN002136 | AN002137 | AN002138 |
---|---|---|---|---|---|---|---|---|---|
Analysis type | MS | MS | MS | MS | MS | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | Reversed phase | Reversed phase | Reversed phase | Reversed phase | Reversed phase | Reversed phase | Reversed phase |
Chromatography system | Waters Acquity | Waters Acquity | Waters Acquity | Waters Acquity | Waters Acquity | Waters Acquity | Waters Acquity | Waters Acquity | Waters Acquity |
Column | Waters Acquity BEH C18 (50 x 1.2mm,1.7um) | Agilent Eclipse XBD C8 (50 x 4.6mm, 1.8um) | Agilent Eclipse XBD C8 (50 x 4.6mm, 1.8um) | Agilent Eclipse XBD C8 (50 x 4.6mm, 1.8um) | Agilent Eclipse XBD C8 (50 x 4.6mm, 1.8um) | Agilent Eclipse XBD C8 (50 x 4.6mm, 1.8um) | Agilent Eclipse XBD C8 (50 x 4.6mm, 1.8um) | Thermo Hypersil Gold C18 (50 x 1.2mm,1.7um) | Agilent Eclipse XDB-PLUS C18 (50 x 1.2mm, 1.8um) |
MS Type | ESI | ESI | ESI | ESI | ESI | ESI | ESI | ESI | ESI |
MS instrument type | Triple quadrupole | Triple quadrupole | Triple quadrupole | Triple quadrupole | Triple quadrupole | Triple quadrupole | Triple quadrupole | Triple quadrupole | Triple quadrupole |
MS instrument name | ABI Sciex 5500 QTrap | ABI Sciex 5500 QTrap | ABI Sciex 5500 QTrap | ABI Sciex 5500 QTrap | ABI Sciex 5500 QTrap | ABI Sciex 5500 QTrap | ABI Sciex 5500 QTrap | ABI Sciex 5500 QTrap | ABI Sciex 5500 QTrap |
Ion Mode | POSITIVE | POSITIVE | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE | POSITIVE | POSITIVE | POSITIVE |
Units | nM | nM | nM | nM | nM | nM | nM | nM | nM |
Chromatography:
Chromatography ID: | CH001562 |
Chromatography Summary: | Molecular species were resolved by reversed-phase liquid chromatography in the presence of class and sub-class specific internal standard compounds added to each sample. Selectivity was further enhanced by scheduling the detection of each compound according to its elution from the high-performance liquid chromatography (HPLC) column, known as scheduled MRM (sMRM). |
Instrument Name: | Waters Acquity |
Column Name: | Waters Acquity BEH C18 (50 x 1.2mm,1.7um) |
Internal Standard: | DG(28:0)-d5, DG(30:0)-d5, DG(32:0)-d5, DG(34:0)-d5, DG(38:0)-d5, DG(40:10)-d5, DG(40:8)-d5, DG(40:4)-d5, DG(40:0)-d5, TG(44:1)-d5, TG(48:1)-d5, TG(50:0)-d5, TG(51:1)-d5, TG(58:10)-d5, TG(58:7)-d5, TG(62:16)-d5, TG(60:1)-d5 |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH001563 |
Chromatography Summary: | Molecular species were resolved by reversed-phase liquid chromatography in the presence of class and sub-class specific internal standard compounds added to each sample. Selectivity was further enhanced by scheduling the detection of each compound according to its elution from the high-performance liquid chromatography (HPLC) column, known as scheduled MRM (sMRM). |
Instrument Name: | Waters Acquity |
Column Name: | Agilent Eclipse XBD C8 (50 x 4.6mm, 1.8um) |
Internal Standard: | LPC(17:0), PC(37:4), LPE(17:1), PE(37:4) |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH001564 |
Chromatography Summary: | Molecular species were resolved by reversed-phase liquid chromatography in the presence of class and sub-class specific internal standard compounds added to each sample. Selectivity was further enhanced by scheduling the detection of each compound according to its elution from the high-performance liquid chromatography (HPLC) column, known as scheduled MRM (sMRM). |
Instrument Name: | Waters Acquity |
Column Name: | Thermo Hypersil Gold C18 (50 x 1.2mm,1.7um) |
Internal Standard: | C17 Sphingosine, C17 Sphinganine,Cer(d18:1/12:0), GlcCer(d18:1/12:0), LacCer(d18:1/12:0) |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH001565 |
Chromatography Summary: | Molecular species were resolved by reversed-phase liquid chromatography in the presence of class and sub-class specific internal standard compounds added to each sample. Selectivity was further enhanced by scheduling the detection of each compound according to its elution from the high-performance liquid chromatography (HPLC) column, known as scheduled MRM (sMRM). |
Instrument Name: | Waters Acquity |
Column Name: | Agilent Eclipse XDB-PLUS C18 (50 x 1.2mm, 1.8um) |
Chromatography Type: | Reversed phase |