Return to study ST003012 main page
MB Sample ID: SA327108
Local Sample ID: | DS1-27-53 |
Subject ID: | SU003126 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Gender: | Female |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004944 | AN004945 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) | Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | NEGATIVE | POSITIVE |
Units | peak area | peak area |
Chromatography:
Chromatography ID: | CH003732 |
Chromatography Summary: | Negative C18 |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) |
Column Temperature: | 45 |
Flow Gradient: | 0-0.5 min 0% B, 0.5-1.1 min 0-100% B, 1.1-2.75 min hold at 100% B, 2.75-3 min 100-0% B, 3-5 min hold at 0% B |
Flow Rate: | 450 uL/min |
Sample Injection: | 6 uL |
Solvent A: | 95% water 5% acetonitrile 1 mM ammonium acetate |
Solvent B: | 95% acetonitrile 5% water 1 mM ammonium acetate |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH003733 |
Chromatography Summary: | Positive C18 |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) |
Column Temperature: | 45 |
Flow Gradient: | 0-0.5 min 5% B, 0.5-1.1 min 5-95% B, 1.1-2.75 min hold at 95% B, 2.75-3 min 95-5% B, 3-5 min hold at 5% B |
Flow Rate: | 450 uL/min |
Sample Injection: | 6 uL |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100%acetonitrile; 0.1% formic acid |
Chromatography Type: | Reversed phase |