Summary of Study ST003167
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001970. The data can be accessed directly via it's Project DOI: 10.21228/M8314P This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST003167 |
Study Title | Metabolomics of Human CD19-BBz CD8 CAR-T cells with low and high MCJ expression |
Study Summary | The goal of these experiments are to characterize the metabolic profile of the human CD8 CD19-BBz CAR-T cells from donors with high or low MCJ expression after 3 expansions (6 days) with IL-2 (100IU/ml). |
Institute | University of Colorado School of Medicine |
Laboratory | Laboratory of Angelo D'Alessandro in collaboration with Mercedes Rincon |
Last Name | Cendali |
First Name | Francesca |
Address | 13199 East Montview Boulevard, Aurora, CO, 80045, USA |
francesca.cendali@cuanschutz.edu | |
Phone | 3037246131 |
Submit Date | 2024-04-11 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2024-05-02 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005196 | AN005197 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Phenomenex Kinetex C18 (30 x 2.1mm, 1.7um) | Phenomenex Kinetex C18 (30 x 2.1mm, 1.7um) |
MS Type | ESI | ESI |
MS instrument type | Exploris120 | Exploris120 |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | NEGATIVE | POSITIVE |
Units | Peak Areas | Peak Areas |
Chromatography:
Chromatography ID: | CH003931 |
Chromatography Summary: | Negative ion Mode |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 (30 x 2.1mm, 1.7um) |
Column Temperature: | 45 |
Flow Gradient: | 0-0.2 min 5% B, 0.2-.8 min hold at 95% B, .8-.81 min 95-5% B, .81-1 min hold at 5% B. |
Flow Rate: | 0.450 ml/min |
Solvent A: | 100% Water; 10mM Ammonium acetate, .01% Formic Acid |
Solvent B: | 50% Methanol/ 50% Acetonitrile; 10mM Ammonium acetate, .01% Formic Acid |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH003932 |
Chromatography Summary: | Positive Ion Mode |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 (30 x 2.1mm, 1.7um) |
Column Temperature: | 45 |
Flow Gradient: | 0-0.3 min 5% B, 0.3-.8 min hold at 95% B, .8-.81 min 95-5% B, .81-1 min hold at 5% B. |
Flow Rate: | 0.450 ml/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile; 0.1% formic acid |
Chromatography Type: | Reversed phase |