Summary of Study ST001224
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000821. The data can be accessed directly via it's Project DOI: 10.21228/M8JX05 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001224 |
Study Title | Vaginal swab lipidome profiles at 48 h reflect the fat composition of neonatal diet during first two days postnatal |
Study Type | MRM-profiling |
Study Summary | In this study, we further investigated the efficacy of using MRM-profiling of vaginal lipids to differentiate PND 2 vaginal swabs between gilts suckled by sow or fed milk replacer. Secondly, we tested the effect of a lard based supplement on vaginal lipid profiles of gilts. |
Institute | Purdue University |
Department | Animal Sciences |
Laboratory | Metabolite Profiling Facility - Purdue University |
Last Name | Ferreira |
First Name | Christina |
Address | 1203 W. State St, West Lafayette, IN, 47906, USA |
cferrei@purdue.edu | |
Phone | 7654095924 |
Submit Date | 2019-06-06 |
Num Groups | colostrum suckled (S, n=8); S plus fat supplement (SF, n=5); bottle-fed milk replacer (B, n=8); or B plus fat supplement (BF, n=7 |
Total Subjects | 28 |
Num Females | 28 |
Raw Data Available | Yes |
Raw Data File Type(s) | d |
Analysis Type Detail | LC-MS |
Release Date | 2019-09-23 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002037 |
---|---|
Analysis type | MS |
Chromatography type | Unspecified |
Chromatography system | Agilent 6410 |
Column | none |
MS Type | ESI |
MS instrument type | Triple quadrupole |
MS instrument name | Agilent 6410 QQQ |
Ion Mode | UNSPECIFIED |
Units | ion counts |
MS:
MS ID: | MS001889 |
Analysis ID: | AN002037 |
Instrument Name: | Agilent 6410 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Pooled sample injections (8 µl) were delivered to the micro-autosampler (G1377A) in a QQQ6410 triple quadrupole mass spectrometer (Agilent Technologies, San Jose, CA) equipped with an ESI ion source. The solvent pumped between injections (CapPump G1376A, Agilent Technologies, San Jose, CA) was acetonitrile with 1% formic acid at 10µL/min. Between sample injections, methanol/chloroform was injected to remove any remaining lipids before the next sample injection |
Ion Mode: | UNSPECIFIED |