MoNA MS database records for (R)-( )-propranolol

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
AU110801Bruker maXis ImpactLC-ESI-QTOFESI10 eV[M+H]+positiveMS2
AU110802Bruker maXis ImpactLC-ESI-QTOFESI20 eV[M+H]+positiveMS2
AU110803Bruker maXis ImpactLC-ESI-QTOFESI30 eV[M+H]+positiveMS2
AU110804Bruker maXis ImpactLC-ESI-QTOFESI40 eV[M+H]+positiveMS2
AU110805Bruker maXis ImpactLC-ESI-QTOFESI50 eV[M+H]+positiveMS2
EA017102LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI15 % (nominal)[M+H]+positiveMS2
EA017108LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI15 % (nominal)[M+H]+positiveMS2
EA017103LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI30 % (nominal)[M+H]+positiveMS2
EA017109LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI30 % (nominal)[M+H]+positiveMS2
EA017101LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI35 % (nominal)[M+H]+positiveMS2
EA017114LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI35 % (nominal)[M+H]+positiveMS2
EA017104LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI45 % (nominal)[M+H]+positiveMS2
EA017110LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI45 % (nominal)[M+H]+positiveMS2
EA017105LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI60 % (nominal)[M+H]+positiveMS2
EA017111LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI60 % (nominal)[M+H]+positiveMS2
EA017106LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI75 % (nominal)[M+H]+positiveMS2
EA017112LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI75 % (nominal)[M+H]+positiveMS2
EA017107LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI90 % (nominal)[M+H]+positiveMS2
EA017113LTQ Orbitrap XL Thermo Scienti...LC-ESI-ITFTESI90 % (nominal)[M+H]+positiveMS2
EQ017101Q Exactive Orbitrap Thermo Sci...LC-ESI-QFTESI15 (nominal)[M+H]+positiveMS2
EQ017102Q Exactive Orbitrap Thermo Sci...LC-ESI-QFTESI30 (nominal)[M+H]+positiveMS2
EQ017103Q Exactive Orbitrap Thermo Sci...LC-ESI-QFTESI45 (nominal)[M+H]+positiveMS2
EQ017104Q Exactive Orbitrap Thermo Sci...LC-ESI-QFTESI60 (nominal)[M+H]+positiveMS2
EQ017105Q Exactive Orbitrap Thermo Sci...LC-ESI-QFTESI75 (nominal)[M+H]+positiveMS2
EQ017106Q Exactive Orbitrap Thermo Sci...LC-ESI-QFTESI90 (nominal)[M+H]+positiveMS2
SM855601Q Exactive Plus Orbitrap Therm...LC-ESI-QFTESI35 (nominal)[M+H]+positiveMS2
UA006101Q Exactive Plus Orbitrap Therm...LC-ESI-QFTESI50 % (nominal)[M+H]+positiveMS2
WA001110ZQ, WatersLC-ESI-QESI--positiveMS1
WA001111ZQ, WatersLC-ESI-QESI--positiveMS1
WA001112ZQ, WatersLC-ESI-QESI--positiveMS1
WA001113ZQ, WatersLC-ESI-QESI--positiveMS1
WA001114ZQ, WatersLC-ESI-QESI--positiveMS1
KO003927API3000, Applied BiosystemsLC-ESI-QQ-10 V[M+H]+positiveMS2
KO003928API3000, Applied BiosystemsLC-ESI-QQ-20 V[M+H]+positiveMS2
KO003929API3000, Applied BiosystemsLC-ESI-QQ-30 V[M+H]+positiveMS2
KO003930API3000, Applied BiosystemsLC-ESI-QQ-40 V[M+H]+positiveMS2
KO003931API3000, Applied BiosystemsLC-ESI-QQ-50 V[M+H]+positiveMS2
KO009171LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.8[M+H]+positiveMS2
KO009175LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.80/0.55[M+H]+positiveMS3
KO009174LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.80/0.60[M+H]+positiveMS3
KO009172LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.80/0.70[M+H]+positiveMS3
KO009173LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.80/0.70[M+H]+positiveMS3
HMDB0001849_ms_ms_1708LC/MSD Trap XCT, Agilent Techn...Quattro_QQQ---positiveMS2
HMDB0001849_ms_ms_1709LC/MSD Trap XCT, Agilent Techn...Quattro_QQQ---positiveMS2
HMDB0001849_ms_ms_1710LC/MSD Trap XCT, Agilent Techn...Quattro_QQQ---positiveMS2