MoNA MS database records for 17alpha-hydroxyprogesterone
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
AU239757 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
AU239758 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
AU239759 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
AU239701 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU239702 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU239703 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU239704 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU239705 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU239706 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 22.2-33.3 eV | [M+H]+ | positive | MS2 |
LU114401 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M+H]+ | positive | MS2 |
LU114402 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M+H]+ | positive | MS2 |
LU114403 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M+H]+ | positive | MS2 |
LU114404 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M+H]+ | positive | MS2 |
LU114405 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M+H]+ | positive | MS2 |
LU114406 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M+H]+ | positive | MS2 |
MoNA041695 | Agilent 6560 | - | - | 20 | [M+H]+ | positive | - |
MoNA041766 | Agilent 6560 | - | - | 40 | [M+H]+ | positive | - |
JP005735 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
CCMSLIB00000085500 | qTof | - | - | - | [M+H]+ | positive | MS2 |
VF-NPL-LTQ006603 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ006604 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
VF-NPL-LTQ006601 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ006602 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS3 Composite |
VF-NPL-QEHF000253 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000254 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000255 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000256 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000257 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000258 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
HMDB0000374_ms_ms_588 | Thermo Q Exactive HF | Quattro_QQQ | - | - | - | positive | - |
HMDB0000374_ms_ms_589 | Thermo Q Exactive HF | Quattro_QQQ | - | - | - | positive | - |
HMDB0000374_ms_ms_590 | Thermo Q Exactive HF | Quattro_QQQ | - | - | - | positive | - |
HMDB0000374_c_ms_2225 | Thermo Q Exactive HF | GC-MS | - | - | - | - | - |
HMDB0000374_ei_ms_1116 | Thermo Q Exactive HF | - | - | - | - | - | - |