MoNA MS database records for Camptothecin
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PR311099 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M+H]+ | positive | MS2 |
BML00443 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M-H]- | negative | MS2 |
BML00453 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M-H]- | negative | MS2 |
BML00463 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M-H]- | negative | MS2 |
BML80871 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML80873 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | negative | MS1 |
BML00403 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M+H]+ | positive | MS2 |
BML00417 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M+H]+ | positive | MS2 |
BML00431 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M+H]+ | positive | MS2 |
BML80870 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML80872 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
CCMSLIB00000005871 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000005872 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000005873 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000005874 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000005875 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000005876 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000005877 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000005878 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000005879 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000078088 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00004679953 | qTof | - | - | - | [M+H]+ | positive | MS2 |
VF-NPL-LTQ006466 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
VF-NPL-QEHF003424 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF003425 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF003426 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF003430 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF003431 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF003432 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF003427 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF003428 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF003429 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
Bruker_HCD_library000179 | Thermo Q Exactive HF | - | - | - | [M-H]- | negative | MS2 |
EAD000881 | Thermo Q Exactive HF | - | - | - | [M+H]+ | - | - |