Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
Bruker_HCD_library000842 | - | - | - | [M+Cl]- | negative | MS2 | |
VF-NPL-QEHF000226 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000227 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000228 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
AU112001 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU112002 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU112003 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU112004 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU112005 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU112006 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 19.3-29.0 eV | [M+H]+ | positive | MS2 |
CCMSLIB00000078241 | qTof | - | - | - | [M+H]+ | positive | MS2 |
EA019401 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
EA019402 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA019403 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA019404 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA019405 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA019406 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA019407 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA019408 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA019409 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA019410 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA019411 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA019412 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA019413 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA019414 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
FiehnHILIC000240 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001814 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FIO01104 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
FIO01105 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
FIO01106 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
FIO01107 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
FIO01108 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
LU126601 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M+H]+ | positive | MS2 |
LU126602 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M+H]+ | positive | MS2 |
LU126603 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M+H]+ | positive | MS2 |
LU126604 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M+H]+ | positive | MS2 |
LU126605 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M+H]+ | positive | MS2 |
LU126606 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M+H]+ | positive | MS2 |
UA003001 | LTQ Orbitrap XL Thermo Scienti... | ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
UA003003 | LTQ Orbitrap XL Thermo Scienti... | APCI-ITFT | APCI | 35 % (nominal) | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000229 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000230 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000231 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF006982 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF006983 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF006984 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000097 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-LTQ000098 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS4 Composite |
VF-NPL-QEHF000232 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF000233 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF000234 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF006985 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF006986 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
HMDB0014704_ei_ms_534 | Agilent 6530 Q-TOF | - | - | - | - | - | - |
WA001146 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001147 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001148 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001149 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001150 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |