MoNA MS database records for Chloramphenicol
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
AU230657 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
AU230658 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
AU230659 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
AU230660 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
AU230662 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 24.8-37.3 eV | [M-H]- | negative | MS2 |
AU230601 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU230602 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU230603 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU230604 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU230605 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU230606 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 22.1-33.1 eV | [M+H]+ | positive | MS2 |
UF407353 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M-H]- | negative | MS2 |
UF407351 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
UF407354 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
UF407352 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M-H]- | negative | MS2 |
UF407303 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF407301 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF407304 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF407302 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
LU066251 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M-H]- | negative | MS2 |
LU066252 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M-H]- | negative | MS2 |
LU066253 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M-H]- | negative | MS2 |
LU066255 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M-H]- | negative | MS2 |
LU066256 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M-H]- | negative | MS2 |
EQ307051 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 15 (nominal) | [M-H]- | negative | MS2 |
EQ307052 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 30 (nominal) | [M-H]- | negative | MS2 |
EQ307053 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 45 (nominal) | [M-H]- | negative | MS2 |
EQ307054 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 60 (nominal) | [M-H]- | negative | MS2 |
EQ307055 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 75 (nominal) | [M-H]- | negative | MS2 |
EQ307056 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 90 (nominal) | [M-H]- | negative | MS2 |
EQ307001 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 15 (nominal) | [M+H]+ | positive | MS2 |
EQ307002 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 30 (nominal) | [M+H]+ | positive | MS2 |
EQ307003 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 45 (nominal) | [M+H]+ | positive | MS2 |
EQ307004 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 60 (nominal) | [M+H]+ | positive | MS2 |
EQ307005 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 75 (nominal) | [M+H]+ | positive | MS2 |
EQ307006 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 90 (nominal) | [M+H]+ | positive | MS2 |
SM831851 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M-H]- | negative | MS2 |
SM831806 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
CB000288 | ABSciex API3200 LC/MS system | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS1 |
BML00987 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M-H]- | negative | MS2 |
BML00995 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M-H]- | negative | MS2 |
BML80921 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML80923 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | negative | MS1 |
BML00960 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M+H]+ | positive | MS2 |
BML00969 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M+H]+ | positive | MS2 |
BML80920 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML80922 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
VF-NPL-QTOF007054 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007055 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007056 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
KO000456 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
KO000457 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
KO000458 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
KO000459 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
KO000460 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
KO008918 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.6 | [M+H]+ | positive | MS2 |
KO008919 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.60/0.70 | [M+H]+ | positive | MS3 |
KO008920 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 1.00/0.70 | [M+H]+ | positive | MS3 |
KO008921 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.60/1.00/0.55 | [M+H]+ | positive | MS4 |
CCMSLIB00000004910 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000004911 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000004912 | qTof | - | - | - | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000187 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ000188 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-LTQ000185 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ000186 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS4 Composite |
VF-NPL-QEHF000406 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000407 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000408 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000409 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000410 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000411 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
Bruker_HCD_library000147 | Thermo Q Exactive HF | - | - | - | [M-H]- | negative | MS2 |
EAD000672 | Thermo Q Exactive HF | - | - | - | [M+H]+ | - | - |
EAD000810 | Thermo Q Exactive HF | - | - | - | [M+NH4]+ | - | - |