MoNA MS database records for Chlorogenic acid
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA017770 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
MoNA017771 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
MoNA017772 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M-H]- | negative | MS2 |
MoNA017773 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M-H]- | negative | MS2 |
PM000301 | API 3000 | QqQ | ESI | 35 | [M-H]- | negative | MS2 |
PM007403 | API 3000 | QqQ | ESI | 35V | [M-H]- | negative | MS2 |
PM004318 | Esquire | QIT | ESI | - | [M+H]+ | positive | MS2 |
PM004319 | Esquire | QIT | ESI | - | [M+H]+ | positive | MS2 |
PM004320 | Esquire | QIT | ESI | - | [M+H]+ | positive | MS2 |
PM011201 | LCQ | QIT | ESI | 35% | [M-H]- | negative | MS2 |
PM017702 | LTQ | QIT | ESI | 35% | [M+H]+ | positive | MS2 |
FIO00623 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
FIO00624 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
FIO00625 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
FIO00626 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
FIO00627 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 50 eV | [M-H]- | negative | MS2 |
FIO00618 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
FIO00619 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
FIO00620 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
FIO00621 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
FIO00622 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
PB005541 | micrOTOF-Q | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
PB006181 | micrOTOF-Q | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB006182 | micrOTOF-Q | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
PM017001 | QTOF Ultima API | Q-TOF | ESI | 10V | [M-H]- | negative | MS2 |
PM017002 | QTOF Ultima API | Q-TOF | ESI | 10V | [M-H]- | negative | MS2 |
PS063607 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS063608 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
PS063609 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M-H]- | negative | MS2 |
PS063610 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M-H]- | negative | MS2 |
PS063611 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M-H]- | negative | MS2 |
PS063601 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS063602 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS063603 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS063604 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS063605 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PM006104 | XCT | QIT | ESI | - | [M-H]- | negative | MS2 |
VF-NPL-QTOF003402 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007057 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003403 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007058 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003404 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007059 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF002147 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002148 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002149 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF003405 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007060 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003406 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007061 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003407 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007062 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002150 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002151 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002152 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
MoNA033183 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA033184 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA033186 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
KO000466 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
KO000467 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
KO000468 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
KO000469 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
KO000470 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
KO002577 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO002578 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO002579 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO002580 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO002581 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
CCMSLIB00000579204 | Ion Trap | - | - | - | [M-H]- | negative | MS2 |
KO008922 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.8 | [M+H]+ | positive | MS2 |
KO008923 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.80/0.50 | [M+H]+ | positive | MS3 |
FiehnLib000108 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000109 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00004684246 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
MoNA042786 | Orbitrap | - | - | - | 2M+Na | positive | - |
CCMSLIB00004684185 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
MoNA042785 | Orbitrap | - | - | - | M+H | positive | - |
MoNA042784 | Orbitrap | - | - | - | M+Na | positive | - |
MoNA042787 | Orbitrap | - | - | - | M+Na | positive | - |
OUF00135 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
OUF00136 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00000081766 | qTof | - | - | - | [M-H]- | negative | MS2 |
FiehnHILIC001832 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000309 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ000310 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS3 Composite |
VF-NPL-LTQ000307 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ000308 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS4 Composite |
VF-NPL-QEHF011308 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF011309 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF011310 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
FiehnHILIC001117 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
VF-NPL-QEHF011320 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF011321 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF011322 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
MoNA037541 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
VF-NPL-QEHF011314 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF011315 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF011316 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF011311 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF011312 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF011313 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF011317 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF011318 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF011319 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+NH4]+ | positive | MS2 |
JP000136 | Unknown | FD-B | - | - | [M]+* | positive | MS1 |
Bruker_HCD_library001839 | Unknown | - | - | - | [M+H]+ | positive | MS2 |
HMDB0003164_ms_ms_2209 | Unknown | Quattro_QQQ | - | - | - | positive | - |
HMDB0003164_ms_ms_2210 | Unknown | Quattro_QQQ | - | - | - | positive | - |
HMDB0003164_ms_ms_2211 | Unknown | Quattro_QQQ | - | - | - | positive | - |
EAD000935 | Unknown | - | - | - | [M+H]+ | - | - |
EAD001143 | Unknown | - | - | - | [M+Na]+ | - | - |
EAD001103 | Unknown | - | - | - | [M+NH4]+ | - | - |
HMDB0003164_c_ms_2240 | Unknown | GC-MS | - | - | - | - | - |