MoNA MS database records for Cytisine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
NA003387 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 100% (nominal) | [M+H]+ | positive | MS2 |
NA003388 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 105% (nominal) | [M+H]+ | positive | MS2 |
NA002633 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35% (nominal) | [M+H]+ | positive | MS2 |
NA002634 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 40% (nominal) | [M+H]+ | positive | MS2 |
NA002635 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45% (nominal) | [M+H]+ | positive | MS2 |
NA002636 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 50% (nominal) | [M+H]+ | positive | MS2 |
NA002637 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55% (nominal) | [M+H]+ | positive | MS2 |
NA003016 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60% (nominal) | [M+H]+ | positive | MS2 |
NA003017 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 65% (nominal) | [M+H]+ | positive | MS2 |
NA003018 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 70% (nominal) | [M+H]+ | positive | MS2 |
NA003019 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75% (nominal) | [M+H]+ | positive | MS2 |
NA003020 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80% (nominal) | [M+H]+ | positive | MS2 |
NA003384 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 85% (nominal) | [M+H]+ | positive | MS2 |
NA003385 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90% (nominal) | [M+H]+ | positive | MS2 |
NA003386 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 95% (nominal) | [M+H]+ | positive | MS2 |
BML00001 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M+H]+ | positive | MS2 |
BML00014 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M+H]+ | positive | MS2 |
BML00027 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M+H]+ | positive | MS2 |
BML81035 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML81037 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
VF-NPL-QTOF007249 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007250 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007251 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-LTQ006415 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-LTQ006416 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS3 Composite |
VF-NPL-QEHF003328 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF003329 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF003330 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF003337 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF003338 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF003339 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF003334 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF003335 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF003336 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF003331 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF003332 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF003333 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
Bruker_HCD_library001929 | Thermo Q Exactive HF | - | - | - | [M+H]+ | positive | MS2 |