MoNA MS database records for L-Arginine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA002618 | - | Electrospray Ionization (ESI) | - | [M+H]+ | positive | MS2 | |
MoNA002619 | - | Electrospray Ionization (ESI) | - | [M+H]+ | positive | MS2 | |
MoNA003270 | - | Electrospray Ionization (ESI) | - | [M+H]+ | positive | MS2 | |
MoNA003271 | - | Electrospray Ionization (ESI) | - | [M+H]+ | positive | MS2 | |
MoNA003272 | - | Electrospray Ionization (ESI) | - | - | positive | - | |
MoNA003273 | - | Electrospray Ionization (ESI) | - | [M+H]+ | positive | MS2 | |
MoNA003274 | - | Electrospray Ionization (ESI) | - | [M+H]+ | positive | MS2 | |
MoNA003383 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 10(NCE) | [M+H]+ | positive | MS2 | |
MoNA003384 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 30(NCE) | [M+H]+ | positive | MS2 | |
MoNA003385 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 40(NCE) | [M+H]+ | positive | MS2 | |
MoNA003386 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 50(NCE) | [M+H]+ | positive | MS2 | |
MoNA003387 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 70(NCE) | [M+H]+ | positive | MS2 | |
MoNA003388 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 90(NCE) | [M+H]+ | positive | MS2 | |
CE000262 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 15.0eV | [M+H]+ | positive | MS2 |
CE000263 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 25.0eV | [M+H]+ | positive | MS2 |
CE000264 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 75.0eV | [M+H]+ | positive | MS2 |
CE000265 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 20.0eV | [M+H]+ | positive | MS2 |
CE000266 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35.0eV | [M+H]+ | positive | MS2 |
CE000267 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 40.0eV | [M+H]+ | positive | MS2 |
CE000268 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 65.0eV | [M+H]+ | positive | MS2 |
CE000269 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 60.0eV | [M+H]+ | positive | MS2 |
CE000273 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 55.0eV | [M+H]+ | positive | MS2 |
KNA00093 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
KNA00095 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
KNA00096 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS2 |
KNA00412 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
KNA00413 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
KNA00414 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS2 |
KNA00415 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+Na]+ | positive | MS2 |
KNA00503 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | negative | MS1 |
KNA00505 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M-H]- | negative | MS2 |
KNA00506 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | negative | MS2 |
KNA00784 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | negative | MS1 |
KNA00786 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M-H]- | negative | MS2 |
KNA00787 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | negative | MS2 |
MoNA019821 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
MoNA019822 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
MoNA019823 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M+H]+ | positive | MS2 |
MoNA019824 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
MoNA024248 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MT000042 | LTQ XL, Thermo Finnigan | LC-ESI-IT | ESI | 40 | [M+H]+ | positive | MS2 |
PB000419 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
PB000420 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M+H]+ | positive | MS2 |
PB000421 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
PM000946 | API 2000 | QqQ | ESI | 32 | [M+H]+ | positive | MS2 |
PR030002 | CE-system connected to 6210 Ti... | CE-ESI-TOF | ESI | - | [M+H]+ | positive | MS1 |
PR100157 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100158 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 V | [M+H]+ | positive | MS2 |
PR100303 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100578 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR100733 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PS026501 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS026502 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS026503 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS026504 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS026505 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PS026507 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS065601 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS065602 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS065603 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS065604 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS065605 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PS065606 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M+H]+ | positive | MS2 |
PT102650 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT102653 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | 30 V | [M+H]+ | positive | MS2 |
PT106560 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT202650 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PT206560 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
RP001201 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
RP001202 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
RP001203 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
BML80770 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML80773 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | negative | MS1 |
CCMSLIB00000479581 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000577958 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00003740025 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464192 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464193 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005464289 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720395 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720688 | qTof | - | - | - | [M-H]- | negative | MS2 |
EMBL-MCF_spec112555 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec356356 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec356376 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M+H]+ | positive | MS2 |
FiehnHILIC000198 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001076 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC001771 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC002601 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
FiehnLib000958 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0000517_c_ms_1414 | Leco Pegasus IV | GC-MS | - | - | - | - | - |
HMDB0000517_c_ms_1500 | Leco Pegasus IV | GC-MS | - | - | - | - | - |
HMDB0000517_ms_ms_740 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0000517_ms_ms_741 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0000517_ms_ms_742 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
KZ000222 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
MoNA001812 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA001813 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA001815 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
MoNA010119 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010120 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010121 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010122 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010123 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010124 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA016940 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
MoNA018958 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA018959 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA018960 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA018961 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA018962 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA018963 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA031874 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA031875 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA031876 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA032009 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032010 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA032011 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA033920 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA033922 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA033923 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA035944 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA035948 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA035950 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA036467 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036468 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA036469 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA037039 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037126 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037832 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038479 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038524 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
PR010030 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |