MoNA MS database records for Lovastatin
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
AU221201 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU221207 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU221202 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU221208 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU221203 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU221209 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU221204 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU221210 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU221205 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU221211 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU221230 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+Na]+ | positive | MS2 |
AU221232 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+Na]+ | positive | MS2 |
AU221233 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+Na]+ | positive | MS2 |
AU221234 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+Na]+ | positive | MS2 |
EQ313901 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 15 (nominal) | [M+H]+ | positive | MS2 |
EQ313902 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 30 (nominal) | [M+H]+ | positive | MS2 |
EQ313903 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 45 (nominal) | [M+H]+ | positive | MS2 |
EQ313904 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 60 (nominal) | [M+H]+ | positive | MS2 |
EQ313905 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 75 (nominal) | [M+H]+ | positive | MS2 |
EQ313906 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 90 (nominal) | [M+H]+ | positive | MS2 |
BML81631 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML81633 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | negative | MS1 |
BML81630 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML81632 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
VF-NPL-QTOF008371 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF008372 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF008373 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF008368 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF008369 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF008370 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
JP009510 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
JP009511 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
HMDB0014372_c_ms_100081 | HITACHI M-80 | EI-B | - | - | - | positive | - |
HMDB0014372_c_ms_100082 | HITACHI M-80 | EI-B | - | - | - | positive | - |
CCMSLIB00005435692 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005435737 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005435739 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005435738 | Orbitrap | - | - | - | [M+NH4]+ | positive | MS2 |
CCMSLIB00000077133 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000077134 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000078413 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000084933 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000839194 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005435663 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000078412 | qTof | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005435666 | qTof | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005435664 | qTof | - | - | - | [M+NH4]+ | positive | MS2 |
VF-NPL-LTQ001717 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-LTQ001718 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS4 Composite |
VF-NPL-LTQ006479 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+Na | positive | MS2 |
VF-NPL-LTQ006480 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+Na | positive | MS2-MS5 Composite |
VF-NPL-QEHF002557 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF002558 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF002559 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF002554 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF003460 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF002555 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF003461 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF002556 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF003462 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF002551 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF003457 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF002552 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF003458 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF002553 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF003459 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
Bruker_HCD_library000428 | Thermo Q Exactive HF | - | - | - | [M+C2H4O2-H]- | negative | MS2 |