MoNA MS database records for Thiamine

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
MoNA018183Agilent 6550 iFunnelLC-ESI-QTOFESI10[M-H]-negativeMS2
MoNA018184Agilent 6550 iFunnelLC-ESI-QTOFESI20[M-H]-negativeMS2
MoNA018185Agilent 6550 iFunnelLC-ESI-QTOFESI30[M-H]-negativeMS2
MoNA018186Agilent 6550 iFunnelLC-ESI-QTOFESI40[M-H]-negativeMS2
PT203500Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M-H]-negativeMS2
PT103500Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M+H]+positiveMS2
PS035001TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS035002TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
PS035003TQD, WatersFlow-injection QqQ/MSESI30[M+H]+positiveMS2
PS035004TQD, WatersFlow-injection QqQ/MSESI40[M+H]+positiveMS2
PS035005TQD, WatersFlow-injection QqQ/MSESI50[M+H]+positiveMS2
PS035006TQD, WatersFlow-injection QqQ/MSESI60[M+H]+positiveMS2
PR100608UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR100203UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M]+positiveMS2
CB000299ABSciex API3200 LC/MS systemLC-ESI-QQQ--[M]+positiveMS1
MoNA018880Agilent 6550 iFunnelLC-ESI-QTOF--[M+H]+positiveMS2
MoNA018883Agilent 6550 iFunnelLC-ESI-QTOF--[M+H]+positiveMS2
MoNA018881Agilent 6550 iFunnelLC-ESI-QTOF-10[M+H]+positiveMS2
MoNA018884Agilent 6550 iFunnelLC-ESI-QTOF-10[M+H]+positiveMS2
MoNA018882Agilent 6550 iFunnelLC-ESI-QTOF-30[M+H]+positiveMS2
MoNA018885Agilent 6550 iFunnelLC-ESI-QTOF-30[M+H]+positiveMS2
MoNA035999Agilent qTOF 6545LC-ESI-QTOF-10 eV[M]+positiveMS2
MoNA035997Agilent qTOF 6545LC-ESI-QTOF-20 eV[M]+positiveMS2
MoNA036001Agilent qTOF 6545LC-ESI-QTOF-40 eV[M]+positiveMS2
KO001933API3000, Applied BiosystemsLC-ESI-QQ-10 V[M-2H]-negativeMS2
KO001934API3000, Applied BiosystemsLC-ESI-QQ-20 V[M-2H]-negativeMS2
KO001935API3000, Applied BiosystemsLC-ESI-QQ-30 V[M-2H]-negativeMS2
KO001936API3000, Applied BiosystemsLC-ESI-QQ-40 V[M-2H]-negativeMS2
KO001937API3000, Applied BiosystemsLC-ESI-QQ-50 V[M-2H]-negativeMS2
KO004186API3000, Applied BiosystemsLC-ESI-QQ-10 V[M+H]+positiveMS2
KO004187API3000, Applied BiosystemsLC-ESI-QQ-20 V[M+H]+positiveMS2
KO004188API3000, Applied BiosystemsLC-ESI-QQ-30 V[M+H]+positiveMS2
KO004189API3000, Applied BiosystemsLC-ESI-QQ-40 V[M+H]+positiveMS2
KO004190API3000, Applied BiosystemsLC-ESI-QQ-50 V[M+H]+positiveMS2
KO009294LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.6[M+H]+positiveMS2
KO009295LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.60/0.55[M+H]+positiveMS3
KO009296LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.60/0.60[M+H]+positiveMS3
CCMSLIB00000479740Orbitrap---[M+H]+positiveMS2
CCMSLIB00000577976Q-Exactive Plus---[M+H]+positiveMS2
VF-NPL-QEHF028204Thermo Q Exactive HFESI-QFT-35HCD[M-H]-negativeMS2
VF-NPL-QEHF028205Thermo Q Exactive HFESI-QFT-45HCD[M-H]-negativeMS2
VF-NPL-QEHF028206Thermo Q Exactive HFESI-QFT-65HCD[M-H]-negativeMS2
MoNA038543Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M]+positiveMS2
VF-NPL-QEHF028201Thermo Q Exactive HFESI-QFT-35HCD[M+H]+positiveMS2
VF-NPL-QEHF028202Thermo Q Exactive HFESI-QFT-45HCD[M+H]+positiveMS2
VF-NPL-QEHF028203Thermo Q Exactive HFESI-QFT-65HCD[M+H]+positiveMS2
VF-NPL-QEHF028210Thermo Q Exactive HFESI-QFT-35HCD[M+K]+positiveMS2
VF-NPL-QEHF028211Thermo Q Exactive HFESI-QFT-45HCD[M+K]+positiveMS2
VF-NPL-QEHF028212Thermo Q Exactive HFESI-QFT-65HCD[M+K]+positiveMS2
VF-NPL-QEHF028207Thermo Q Exactive HFESI-QFT-35HCD[M+Na]+positiveMS2
VF-NPL-QEHF028208Thermo Q Exactive HFESI-QFT-45HCD[M+Na]+positiveMS2
VF-NPL-QEHF028209Thermo Q Exactive HFESI-QFT-65HCD[M+Na]+positiveMS2
VF-NPL-QEHF028213Thermo Q Exactive HFESI-QFT-35HCD[M+NH4]+positiveMS2
VF-NPL-QEHF028214Thermo Q Exactive HFESI-QFT-45HCD[M+NH4]+positiveMS2
VF-NPL-QEHF028215Thermo Q Exactive HFESI-QFT-65HCD[M+NH4]+positiveMS2
EMBL-MCF_spec118270Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M+H]+positiveMS2
MoNA016624XEVO-G2SLC-ESI-QTOF-6V (MS1); Ramp 15V-30V (MSE)[M]+positive-
MoNA016803XEVO-G2SLC-ESI-QTOF-6V (MS1); Ramp 15V-30V (MSE)[M+H]+positive-
HMDB0000235_ms_ms_394XEVO-G2SQuattro_QQQ---N/A-
HMDB0000235_ms_ms_395XEVO-G2SQuattro_QQQ---N/A-
HMDB0000235_ms_ms_396XEVO-G2SQuattro_QQQ---N/A-
Bruker_HCD_library001597XEVO-G2S---[M]+positiveMS2
BAF_UVA_POS000143XEVO-G2S------