MoNA MS database records for Verapamil
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
AU226001 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU226002 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU226003 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU226004 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU226005 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU226006 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 24.7-37.1 eV | [M+H]+ | positive | MS2 |
EA067401 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
EA067402 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA067403 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA067404 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA067405 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA067406 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA067407 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA067408 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA067409 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA067410 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA067411 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA067412 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA067413 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA067414 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
SM855703 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF408101 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF408102 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
UF408103 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF408104 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
WA000603 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA000604 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA000605 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA000606 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA000607 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
BML00815 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M+H]+ | positive | MS2 |
BML00825 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M+H]+ | positive | MS2 |
BML00835 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M+H]+ | positive | MS2 |
BML82330 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML82331 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML82332 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
FiehnHILIC000848 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC002411 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
HMDB0001850_ei_ms_640 | SCIEX TripleTOF 6600 | - | - | - | - | - | - |
HMDB0001850_ms_ms_1711 | SCIEX TripleTOF 6600 | Quattro_QQQ | - | - | - | positive | - |
HMDB0001850_ms_ms_1712 | SCIEX TripleTOF 6600 | Quattro_QQQ | - | - | - | positive | - |
HMDB0001850_ms_ms_1713 | SCIEX TripleTOF 6600 | Quattro_QQQ | - | - | - | positive | - |
KO004261 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO004262 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO004263 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO004264 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO004265 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
KO009311 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.9 | [M+H]+ | positive | MS2 |
KO009312 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.90/0.90 | [M+H]+ | positive | MS3 |
KO009313 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.90/0.80 | [M+H]+ | positive | MS3 |
KO009314 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.90/0.50 | [M+H]+ | positive | MS3 |
KO009315 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.90/0.45 | [M+H]+ | positive | MS3 |
MoNA016814 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
MoNA033153 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA033155 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA033157 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA035328 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA035330 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA035331 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA037528 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038276 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |