MoNA MS database records for Morphine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
HMDB0014440_c_ms_100094 | Unknown | CI-B | - | - | - | positive | - |
JP003177 | Unknown | CI-B | - | - | - | positive | MS1 |
HMDB0014440_c_ms_100093 | Unknown | EI-B | - | - | - | positive | - |
JP003089 | Unknown | EI-B | - | - | [M]+* | positive | MS1 |
BML82457 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
EA274401 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
EA274402 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA274403 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA274404 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA274405 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA274406 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA274407 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA274408 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA274409 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA274410 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA274411 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA274412 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA274413 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA274414 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
WA001090 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001091 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001092 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001093 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001094 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
AU158001 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU158002 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU158003 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU158004 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU158005 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU158007 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU158008 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU158009 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU158010 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU158011 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU158030 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+Na]+ | positive | MS2 |
AU158031 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+Na]+ | positive | MS2 |
AU158032 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+Na]+ | positive | MS2 |
BML82455 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
JEL00043 | JMS-S3000 | MALDI-TOFTOF | - | - | [M+H]+ | positive | MS2 |