MoNA MS database records for Genistein
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
VF-NPL-QTOF007797 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF007798 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF007799 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Cl]- | negative | MS2 |
AU241957 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
AU241958 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
AU241959 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
AU241960 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
AU241962 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 22.8-34.1 eV | [M-H]- | negative | MS2 |
CCMSLIB00000081286 | qTof | - | - | - | [M-H]- | negative | MS2 |
EQ326551 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 15 (nominal) | [M-H]- | negative | MS2 |
EQ326552 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 30 (nominal) | [M-H]- | negative | MS2 |
EQ326553 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 45 (nominal) | [M-H]- | negative | MS2 |
EQ326554 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 60 (nominal) | [M-H]- | negative | MS2 |
EQ326555 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 75 (nominal) | [M-H]- | negative | MS2 |
EQ326556 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 90 (nominal) | [M-H]- | negative | MS2 |
EQ326557 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 120 (nominal) | [M-H]- | negative | MS2 |
EQ326558 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 150 (nominal) | [M-H]- | negative | MS2 |
EQ326559 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 180 (nominal) | [M-H]- | negative | MS2 |
FiehnHILIC000980 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC002518 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
LU076551 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M-H]- | negative | MS2 |
LU076552 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M-H]- | negative | MS2 |
LU076553 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M-H]- | negative | MS2 |
LU076554 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M-H]- | negative | MS2 |
LU076555 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M-H]- | negative | MS2 |
LU076556 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M-H]- | negative | MS2 |
MetaboBASE0059 | impact HD | LC-ESI-TOF | ESI | 20 | [M-H]- | negative | MS2 |
MetaboBASE0060 | impact HD | LC-ESI-TOF | ESI | 50 | [M-H]- | negative | MS2 |
MetaboBASE0061 | impact HD | LC-ESI-TOF | ESI | 40 | [M-H]- | negative | MS2 |
MoNA003266 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | Electrospray Ionization (ESI) | Stepped (NCE 20-30-40%) | [M-H]- | negative | MS2 |
PM001102 | LCQ | QIT | ESI | 45% | [M-H]- | negative | MS2 |
PN000050 | micrOTOF-Q | ESI-TOF | ESI | 25 eV | [M-H]- | negative | MS2 |
PR040019 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005451 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005458 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005464 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005469 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005476 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005483 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005489 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005495 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005502 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005509 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005516 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA005522 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RP017611 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
RP017612 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
RP017613 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M-H]- | negative | MS2 |
SM882751 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M-H]- | negative | MS2 |
UF416251 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
UF416252 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M-H]- | negative | MS2 |
UF416253 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M-H]- | negative | MS2 |
UF416254 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
UF423851 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
UF423852 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M-H]- | negative | MS2 |
UF423853 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M-H]- | negative | MS2 |
UF423854 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
VF-NPL-QEHF000691 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000692 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000693 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013339 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013340 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013341 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013972 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013973 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013974 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QTOF001640 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001641 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001642 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002171 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002172 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002173 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF003795 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003796 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003797 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007803 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007804 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007805 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
AU241901 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU241902 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU241903 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU241904 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU241905 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU241906 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 20-30 eV | [M+H]+ | positive | MS2 |
CCMSLIB00000078106 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000081284 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000847611 | Maxis II HD Q-TOF Bruker | - | - | - | [M+H]+ | positive | MS2 |
CE000011 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
CE000012 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 45eV | [M+H]+ | positive | MS2 |
CE000013 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 55eV | [M+H]+ | positive | MS2 |
EQ326501 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 15 (nominal) | [M+H]+ | positive | MS2 |
EQ326502 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 30 (nominal) | [M+H]+ | positive | MS2 |
EQ326503 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 45 (nominal) | [M+H]+ | positive | MS2 |
EQ326504 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 60 (nominal) | [M+H]+ | positive | MS2 |
EQ326505 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 75 (nominal) | [M+H]+ | positive | MS2 |
EQ326506 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 90 (nominal) | [M+H]+ | positive | MS2 |
EQ326507 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 120 (nominal) | [M+H]+ | positive | MS2 |
EQ326508 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 150 (nominal) | [M+H]+ | positive | MS2 |
EQ326509 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 180 (nominal) | [M+H]+ | positive | MS2 |
FFF00193 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00194 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00195 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00196 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00197 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00198 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00199 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS1 |
FiehnHILIC000092 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001675 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
LU076501 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M+H]+ | positive | MS2 |
LU076502 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M+H]+ | positive | MS2 |
LU076503 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M+H]+ | positive | MS2 |
LU076504 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M+H]+ | positive | MS2 |
LU076505 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M+H]+ | positive | MS2 |
LU076506 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M+H]+ | positive | MS2 |
NA000026 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 10 % (nominal) | [M+H]+ | positive | MS2 |
NA000027 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
NA000028 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 20 % (nominal) | [M+H]+ | positive | MS2 |
NA000029 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 25 % (nominal) | [M+H]+ | positive | MS2 |
NA000030 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
PB000881 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB000882 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M+H]+ | positive | MS2 |
PB000884 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
PB000885 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 55 eV | [M+H]+ | positive | MS2 |
PB005712 | micrOTOF-Q | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
PB005713 | micrOTOF-Q | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB005714 | micrOTOF-Q | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
PB005715 | micrOTOF-Q | LC-ESI-QTOF | ESI | 25 eV | [M+H]+ | positive | MS2 |
PB005721 | micrOTOF-Q | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
PM013602 | QTRAP | QqQ | ESI | 27% | [M+H]+ | positive | MS2 |
PM015811 | TSQ | QqQ | ESI | 30V | [M+H]+ | positive | MS2 |
PN000051 | micrOTOF-Q | ESI-TOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PR020019 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 5.0 V | [M+H]+ | positive | MS1 |
PR040020 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
PR040021 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 eV | [M+H]+ | positive | MS2 |
PR310857 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M+H]+ | positive | MS2 |
PS040001 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS040002 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS040003 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS040004 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
RIKENPlaSMA001900 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001906 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001912 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001918 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001924 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001930 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001936 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001942 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001948 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001954 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001960 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001966 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RP017601 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
RP017602 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
RP017603 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
SM882702 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF416201 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF416202 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
UF416203 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF416204 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF423801 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF423802 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
UF423803 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF423804 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000694 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000695 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000696 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013342 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013343 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013344 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013975 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013976 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013977 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001643 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001644 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001645 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002174 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002175 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002176 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003798 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003799 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003800 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007806 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007807 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007808 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000335 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ000336 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-LTQ000337 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ000338 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS3 Composite |
VF-NPL-LTQ000503 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ000504 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-LTQ000505 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ000506 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
VF-NPL-LTQ003723 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ003724 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS3 Composite |
VF-NPL-LTQ007159 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ007160 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS4 Composite |
VF-NPL-LTQ007161 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ007162 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
CCMSLIB00000081285 | qTof | - | - | - | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF003792 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF003793 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF003794 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF007800 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF007801 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF007802 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
CE000014 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | - | - | positive | MS1 |
HMDB0003217_ms_ms_285617 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0003217_ms_ms_285618 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0003217_ms_ms_285619 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0003217_ms_ms_285620 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
MetaboBASE0058 | impact HD | LC-ESI-TOF | ESI | - | - | negative | - |
OUF00238 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
TY000136 | LCMS-IT-TOF | LC-ESI-ITTOF | - | - | - | positive | MS1 |
TY000137 | LCMS-IT-TOF | LC-ESI-ITTOF | - | - | - | negative | MS1 |