Summary of Study ST001611
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001036. The data can be accessed directly via it's Project DOI: 10.21228/M8SD7T This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST001611 |
Study Title | Mouse model of sarcoma (STS) to characterize tumor vulnerabilities and identify novel targets for anti-cancer treatment |
Study Summary | For metabolomics study, tumor-bearing mice were starved for 6 hours before sarcoma and skeletal muscles were harvested. |
Institute | North Carolina State University |
Last Name | Liu |
First Name | Xiaojing |
Address | Polk Hall, RM 128 |
xliu68@ncsu.edu | |
Phone | 9195154387 |
Submit Date | 2020-11-10 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2021-05-11 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002645 | AN002646 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 |
Column | Waters Xbridge amide (100 x 2.1mm,3.5um) | Waters Xbridge amide (100 x 2.1mm,3.5um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Exactive Plus Orbitrap | Thermo Exactive Plus Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | peak area | peak area |
MS:
MS ID: | MS002457 |
Analysis ID: | AN002645 |
Instrument Name: | Thermo Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | It was operated in the full-scan mode with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch. |
Ion Mode: | POSITIVE |
MS ID: | MS002458 |
Analysis ID: | AN002646 |
Instrument Name: | Thermo Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | It was operated in the full-scan mode with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch. |
Ion Mode: | NEGATIVE |