Return to study ST000444 main page
MB Sample ID: SA022622
Local Sample ID: | WB2-2 |
Subject ID: | SU000465 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Species Group: | Human |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU000465 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Species Group: | Human |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
WB2-2 | SA022622 | FL005549 | Control | Sample Treatment |
Collection:
Collection ID: | CO000459 |
Collection Summary: | Freshly collected human urine |
Sample Type: | Urine |
Treatment:
Treatment ID: | TR000479 |
Treatment Summary: | No treatment was applied |
Sample Preparation:
Sampleprep ID: | SP000472 |
Sampleprep Summary: | Bursting bubbles were generated at ambient conditions by feeding gas (1-100 kPa; 1-100 L/s) through an air diffuser at the bottom of diluted (200 times in ultrapure water) urine solution (50-500 mL). Diffusers with three different pore sizes were tested: 100 µm; 1-10 µm; 0.2-5 µm. The first diffuser was made in house by pulling 10 fused silica capillaries with i.d. 100 µm through a rubber piece. The second diffuser was made from porous ceramics and was purchased from Shiyuan Appliances, Shenzhongshan, Guangdong, China. The third diffuser was made from porous ceramics and was purchased from Junfeng Tradnig Ltd., Ningbo, Zhejiang, China. The bursting bubble aerosol was collected using a slanted glass slide fixed above the liquid surface. Typically, ca. 100 µL of aerosol was collected within 5-10 min from 500 mL bulk solution at the gas pressure of 10 kPa. |
Combined analysis:
Analysis ID | AN000695 |
---|---|
Analysis type | MS |
Chromatography type | Reversed phase |
Chromatography system | Agilent 1100 |
Column | homemade capillary (75ul id,12 cm,Reprosil-Pur Basic C18,3um,100 Å; Dr. Maisch HPLC GmbH,Germany) |
MS Type | ESI |
MS instrument type | LTQ-FT |
MS instrument name | Thermo LTQ-FT Ultra |
Ion Mode | POSITIVE |
Units | Arbitrary Units |
Chromatography:
Chromatography ID: | CH000503 |
Chromatography Summary: | Chromatographic separations were performed on an nano-HPLC Agilent 1100 system (Agilent Technologies) equipped with a homemade capillary column (75 µl id, 12 cm, Reprosil-Pur Basic C18, 3 µm, 100 Å; Dr. Maisch HPLC GmbH, Germany) applying the following binary gradient at a flow rate of 0.3 µl/min: 0.1% formic acid in water (v/v, solvent A) and 0.1% formic acid in acetonitrile (v/v, solvent B), from 3% to 50% (v/v) of solvent B over 90 min followed by isocratic elution (95%, v/v, of solvent B) for 15 min. The injection volume was 1.0 µl (partial loop injection). |
Instrument Name: | Agilent 1100 |
Column Name: | homemade capillary (75ul id,12 cm,Reprosil-Pur Basic C18,3um,100 Å; Dr. Maisch HPLC GmbH,Germany) |
Column Temperature: | Ambient |
Flow Rate: | 0.3 µl/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile; 0.1% formic acid |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS000617 |
Analysis ID: | AN000695 |
Instrument Name: | Thermo LTQ-FT Ultra |
Instrument Type: | LTQ-FT |
MS Type: | ESI |
Ion Mode: | POSITIVE |