Return to study ST001644 main page

MB Sample ID: SA151363

Local Sample ID:79_B8_D14_4S-
Subject ID:SU001721
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002689 AN002690
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) Phenomenex Kinetex C18 (150 x 2.1mm,2.6um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE POSITIVE
Units Relative Abundance Relative Abundance

Chromatography:

Chromatography ID:CH001983
Chromatography Summary:UHPLC-MS metabolomics analyses were performed as described,(1, 3) using a Vanquish UHPLC system coupled online to a high-resolution Q Exactive mass spectrometer (Thermo Fisher, Bremen, Germany). Samples were resolved over a Kinetex C18 column (2.1x150 mm, 1.7 µm; Phenomenex, Torrance, CA, USA) at 45°C. A volume of 10 μl of sample extracts was injected into the UHPLC-MS. Each sample was injected and run with two different chromatographic and MS conditions using a 5 minute gradient at 450 µL/minute from 5-95% B (A: 5% acetonitrile, 95%water/1 mM ammonium acetate; B:95%acetonitrile/5% water, 1 mM ammonium acetate) and the MS was operated in negative ion mode.
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (150 x 2.1mm,2.6um)
Column Temperature:45
Flow Gradient:5 minute gradient from 5-95% B
Flow Rate:450 µL/min
Solvent A:5% acetonitrile/95% water; 1 mM ammonium acetate
Solvent B:95% acetonitrile/5% water; 1 mM ammonium acetate
Chromatography Type:Reversed phase
  
Chromatography ID:CH001984
Chromatography Summary:UHPLC-MS metabolomics analyses were performed as described,(1, 3) using a Vanquish UHPLC system coupled online to a high-resolution Q Exactive mass spectrometer (Thermo Fisher, Bremen, Germany). Samples were resolved over a Kinetex C18 column (2.1x150 mm, 1.7 µm; Phenomenex, Torrance, CA, USA) at 45°C. A volume of 10 μl of sample extracts was injected into the UHPLC-MS. Each sample was injected and run with two different chromatographic and MS conditions, using a 5 minute gradient at 450 µL/minute from 5-95% B (A: water/0.1% formic acid; B:acetonitrile/0.1% formic acid) and the MS was operated in positive mode.
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (150 x 2.1mm,2.6um)
Column Temperature:45
Flow Gradient:5 minute gradient from 5-95% B
Flow Rate:450 µL/min
Solvent A:5% acetonitrile/95% water; 1 mM ammonium acetate
Solvent B:95% acetonitrile/5% water; 1 mM ammonium acetate
Chromatography Type:Reversed phase
  logo