Return to study ST001353 main page
MB Sample ID: SA098178
Local Sample ID: | CKD009 |
Subject ID: | SU001427 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Genotype Strain: | C57BL6J |
Age Or Age Range: | 18-20 weeks |
Weight Or Weight Range: | 20-30g |
Gender: | Male and female |
Animal Animal Supplier: | Jackson Laboratories |
Animal Housing: | 5/cage |
Animal Light Cycle: | 12h |
Animal Feed: | Ad libitum. Control mice received custom casein-diet. Chronic kidney disease was induced by supplementing casein-based diet with 0.15% adenine |
Animal Water: | Ad libitum |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002251 | AN002252 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Dionex | Thermo Dionex |
Column | ACE 5 C18-300 (100 x 2.1mm) | ACE 5 C18-300 (100 x 2.1mm) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Exactive Plus Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | peak height | peak height |
MS:
MS ID: | MS002096 |
Analysis ID: | AN002251 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | samples were processed on a Thermo Q-Exactive Oribtrap mass spectrometer with Dionex UHPLC and autosampler. All samples were analyzed in positive and negative heated electrospray ionization with a mass resolution of 35,000 at m/z 200 as separate injections. Separation was achieved on an ACE 18-pfp 100 x 2.1 mm, 2 µm column with mobile phase A as 0.1% formic acid in water and mobile phase B as acetonitrile. This is a polar embedded stationary phase that provides comprehensive coverage, but does have some limitation is the coverage of very polar species. The flow rate was 350 µL/min with a column temperature of 25°C. 4 µL was injected for negative ions and 2 µL for positive ions. Data from positive and negative ion modes were separately subjected to statistical analyses. MZmine (freeware) was used to identify features, deisotope, align features and perform gap filling to fill in any features that may have been missed in the first alignment algorithm. All adducts and complexes were identified and removed from the data set. The primary source of feature identification was performed by mapping against an internal retention time metabolite library established by the SECIM. Additional metabolite searches were performed using HMDB (http://www.hmdb.ca) and the Metabolomics Workbench (https://www.metabolomicsworkbench.org) through a search of the m/z ratio with a [M+H] adduct and a tolerance of 0.002 m/z. |
Ion Mode: | POSITIVE |
MS ID: | MS002097 |
Analysis ID: | AN002252 |
Instrument Name: | Thermo Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | samples were processed on a Thermo Q-Exactive Oribtrap mass spectrometer with Dionex UHPLC and autosampler. All samples were analyzed in positive and negative heated electrospray ionization with a mass resolution of 35,000 at m/z 200 as separate injections. Separation was achieved on an ACE 18-pfp 100 x 2.1 mm, 2 µm column with mobile phase A as 0.1% formic acid in water and mobile phase B as acetonitrile. This is a polar embedded stationary phase that provides comprehensive coverage, but does have some limitation is the coverage of very polar species. The flow rate was 350 µL/min with a column temperature of 25°C. 4 µL was injected for negative ions and 2 µL for positive ions. Data from positive and negative ion modes were separately subjected to statistical analyses. MZmine (freeware) was used to identify features, deisotope, align features and perform gap filling to fill in any features that may have been missed in the first alignment algorithm. All adducts and complexes were identified and removed from the data set. The primary source of feature identification was performed by mapping against an internal retention time metabolite library established by the SECIM. Additional metabolite searches were performed using HMDB (http://www.hmdb.ca) and the Metabolomics Workbench (https://www.metabolomicsworkbench.org) through a search of the m/z ratio with a [M+H] adduct and a tolerance of 0.002 m/z. |
Ion Mode: | NEGATIVE |