Return to study ST001780 main page

MB Sample ID: SA165096

Local Sample ID:LP25_pre_CSF_M
Subject ID:SU001857
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:25(IQR 22-31)
Gender:Male and female
Human Race:European
Human Medications:None
Human Prescription Otc:None
Human Smoking Status:None
Human Alcohol Drug Use:None

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002890 AN002891
Analysis type MS MS
Chromatography type HILIC Reversed phase
Chromatography system Shimadzu 20AD Shimadzu 20AD
Column Shodex NH2P-40 2E (250 x 2mm,4um) Raptor Biphenyl (150 × 2.1 mm,2.7um)
MS Type ESI ESI
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name ABI Sciex 5500 QTrap ABI Sciex 5500 QTrap
Ion Mode UNSPECIFIED UNSPECIFIED
Units peak area peak area

MS:

MS ID:MS002683
Analysis ID:AN002890
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:The MS/MS detection was performed using electrospray ionization (ESI) on both positive and negative modes. The MS/MS detection was performed using electrospray ionization (ESI) on both positive and negative modes. Advanced scheduled multiple reaction monitoring (MRM) with dynamic windowing and fast polarity switch were used. The ESI source conditions were set as follows: electrospray voltage of -4500 V for negative mode and 5500 V for positive mode, source temperature of 500 °C, curtain gas of 30, ion source gas 1, and gas 2 of 35 psi, respectively.
Ion Mode:UNSPECIFIED
Collision Energy:Compound-dependent
Collision Gas:Medium
Ion Source Temperature:500
Ion Spray Voltage:-4500 V for negative and 5500 V for positive
Ionization:ESI
Mass Accuracy:0.1 Da
Source Temperature:500
  
MS ID:MS002684
Analysis ID:AN002891
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:The MS/MS detection was performed using electrospray ionization (ESI) on both positive and negative modes. The MS/MS detection was performed using electrospray ionization (ESI) on both positive and negative modes. Advanced scheduled multiple reaction monitoring (MRM) with dynamic windowing and fast polarity switch were used. The ESI source conditions were set as follows: electrospray voltage of -4500 V for negative mode and 5500 V for positive mode, source temperature of 500 °C, curtain gas of 30, ion source gas 1, and gas 2 of 35 psi, respectively.
Ion Mode:UNSPECIFIED
Collision Energy:Compound-dependent
Collision Gas:Medium
Ion Source Temperature:500
Ion Spray Voltage:-4500 V for negative and 5500 V for positive
Ionization:ESI
Mass Accuracy:0.1 Da
Source Temperature:500