MB Sample ID: SA218536
Local Sample ID: | D3_TS_A_Hilic_Neg |
Subject ID: | SU002369 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Age Or Age Range: | 61-91 |
Gender: | Female |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003728 | AN003729 | AN003730 | AN003731 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | HILIC | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish | Thermo Vanquish | Thermo Vanquish |
Column | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Obitrap ID-X Tribrid | Obitrap ID-X Tribrid | Obitrap ID-X Tribrid | Obitrap ID-X Tribrid |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | Area integration | Area integration | Area integration | Area integration |
MS:
MS ID: | MS003476 |
Analysis ID: | AN003728 |
Instrument Name: | Obitrap ID-X Tribrid |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Mass spectrometry (MS) data were acquired using the AcquieX acquisition workflow (data dependent analysis). The MS operating parameters were as follows: MS1 mass resolution 60K, for MS2 30K, stepped energy (HCD) 20, 25, 50, scan range 100-1000, RF len (%) 35, AGC gain, intensity threshold 2e4, 25% custom injection mode with an injection time of 54 ms. An extraction blank was used to create a background exclusion list and a pooled QC was used to create the inclusion list. |
Ion Mode: | POSITIVE |
MS ID: | MS003477 |
Analysis ID: | AN003729 |
Instrument Name: | Obitrap ID-X Tribrid |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Mass spectrometry (MS) data were acquired using the AcquieX acquisition workflow (data dependent analysis). The MS operating parameters were as follows: MS1 mass resolution 60K, for MS2 30K, stepped energy (HCD) 20, 25, 50, scan range 100-1000, RF len (%) 35, AGC gain, intensity threshold 2e4, 25% custom injection mode with an injection time of 54 ms. An extraction blank was used to create a background exclusion list and a pooled QC was used to create the inclusion list. |
Ion Mode: | NEGATIVE |
MS ID: | MS003478 |
Analysis ID: | AN003730 |
Instrument Name: | Obitrap ID-X Tribrid |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Mass spectrometry (MS) data were acquired using the AcquieX acquisition workflow (data dependent analysis). The MS operating parameters were as follows: MS1 mass resolution 60K, for MS2 30K, stepped energy (HCD) 20, 25, 50, scan range 100-1000, RF len (%) 35, AGC gain, intensity threshold 2e4, 25% custom injection mode with an injection time of 54 ms. An extraction blank was used to create a background exclusion list and a pooled QC was used to create the inclusion list. |
Ion Mode: | POSITIVE |
MS ID: | MS003479 |
Analysis ID: | AN003731 |
Instrument Name: | Obitrap ID-X Tribrid |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Mass spectrometry (MS) data were acquired using the AcquieX acquisition workflow (data dependent analysis). The MS operating parameters were as follows: MS1 mass resolution 60K, for MS2 30K, stepped energy (HCD) 20, 25, 50, scan range 100-1000, RF len (%) 35, AGC gain, intensity threshold 2e4, 25% custom injection mode with an injection time of 54 ms. An extraction blank was used to create a background exclusion list and a pooled QC was used to create the inclusion list. |
Ion Mode: | NEGATIVE |