Summary of Study ST002016
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001280. The data can be accessed directly via it's Project DOI: 10.21228/M88715 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002016 |
Study Title | Metabolomics of COVID patients |
Study Type | Untargeted Metabolomics |
Study Summary | Untargeted metabolite analysis was performed on a Thermo Orbitrap IDX Tribrid MS to understand changes in metabolites due to COVID severity. |
Institute | University of Virginia |
Department | 1Department of Biochemistry & Molecular Genetics; School of Medicine Core Facilities; Department of Microbiology, Immunology, and Cancer Biology; Department of Biomedical Engineering |
Laboratory | Biomolecular Analysis Facility, Univ of Virginia School of Medicine |
Last Name | Wase |
First Name | Nishikant |
Address | Biomolecular Analysis Facility, Pinn Hall Room No 1105B |
nw5es@virginia.edu | |
Phone | 4023109931 |
Submit Date | 2021-12-14 |
Num Groups | 6 |
Total Subjects | 140 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2022-07-29 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003284 | AN003285 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Thermo Accucore C18 (100 x 2.1mm,2.6um) | Thermo Accucore C18 (100 x 2.1mm,2.6um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Orbitrap ID-X Tribrid | Thermo Orbitrap ID-X Tribrid |
Ion Mode | POSITIVE | NEGATIVE |
Units | intensity | intensity |
Chromatography:
Chromatography ID: | CH002425 |
Chromatography Summary: | Samples were injected in randomized fashion via a Thermo Vanquish UHPLC and separation of the polar metabolites was achieved using Thermo Accucore C18 column (Thermo Scientific; 2.1 x 100 mm; 1.5 µm) maintained at 30 °C. The injection volume was 10 µL. For the 15-minute gradient, the standard mobile phase for RPLC was A = 0.1% formic acid in water and B = 0.1% formic acid in methanol. The linear elution gradient was as follows: 0-8.0 minutes at 50% B, 8.0 – 13.0 minutes held at 98% B, 13.1 to 15.0 minutes revert to 0% B to re-equilibration for next injection at a flow rate of 0.25 mL/min. |
Instrument Name: | Thermo Vanquish |
Column Name: | Thermo Accucore C18 (100 x 2.1mm,2.6um) |
Column Temperature: | 30C |
Flow Gradient: | 0-8 minutes 50% B, 8 - 13 minutes held at 98% B, 13.1 to 15.0 minutes revert to 0% B to re-equilibration for next injection |
Flow Rate: | 0.25 mL/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% methanol; 0.1% formic acid |
Chromatography Type: | Reversed phase |