Summary of Study ST002073

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001315. The data can be accessed directly via it's Project DOI: 10.21228/M8R11F This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002073
Study TitleProfiling of the human intestinal microbiome and bile acids under physiologic conditions using an ingestible sampling device
Study Summary15 human subjects were sample using an ingestible sampling device to target specific regions of the small intestine by using different capsule types (capsule types 1 to 4). Stool was also analyzed.
Institute
University of California, Davis
Last NameFolz
First NameJake
Address451 Health Sciences Drive
Emailjfolz@ucdavis.edu
Phone(530) 752-8129
Submit Date2022-02-01
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2022-12-15
Release Version1
Jake Folz Jake Folz
https://dx.doi.org/10.21228/M8R11F
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003380
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Waters Acquity BEH C18 (100 x 2mm,1.7um)
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name Thermo TSQ Vantage
Ion Mode NEGATIVE
Units ng/mL

Chromatography:

Chromatography ID:CH002498
Chromatography Summary:Samples were analyzed using a Thermofisher Vanquish UHPLC system coupled to a Thermofisher TSQ Altis triple-quadrupole mass spectrometer. An Aquity BEH C18 column (1.7 µm, 2.1 mm×100 mm) with guard column Acquity BEH C18 (1.7 µm, 2.1 mm×5 mm) was used for chromatographic separation with mobile phases of A: LC-MS-grade water with 0.1% formic acid, and B: LC-MS-grade acetonitrile with 0.1% formic acid with a flow rate of 400 µL/min and column temperature of 50 °C. The gradient began at 20% B for 1 min, then shifted to 45% B between 1 and 11 min, then to 95% B between 11 and 14 min, then to 99% B between 14 and 14.5 min, 99% B was maintained until 15.5 min, then transitioned from 99% B to 20% B between 15.5 and 16.5 min, and maintained at 20% B until 18 min. Injection volume was 5 µL and MRM scans were collected for all bile acids and internal standards.
Instrument Name:Thermo Vanquish
Column Name:Waters Acquity BEH C18 (100 x 2mm,1.7um)
Column Temperature:50
Flow Gradient:The gradient began at 20% B for 1 min, then shifted to 45% B between 1 and 11 min, then to 95% B between 11 and 14 min, then to 99% B between 14 and 14.5 min, 99% B was maintained until 15.5 min, then transitioned from 99% B to 20% B between 15.5 and 16.5 min, and maintained at 20% B until 18 min.
Flow Rate:400 uL/min
Sample Injection:5 ul
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:Reversed phase
  logo