This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001315. The data can be accessed directly via it's Project DOI: 10.21228/M8R11F This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002075 |
Study Title | Profiling of the human intestinal microbiome and bile acids under physiologic conditions using an ingestible sampling device (Part 2) |
Study Summary | 15 Subjects were sampled using ingestible sampling device. Device sampled regions of the small intestine depending on design of sampling device. |
Institute | University of California, Davis |
Last Name | Folz |
First Name | Jacob |
Address | 451 Health Sciences Drive |
jfolz@ucdavis.edu | |
Phone | (530) 752-8129 |
Submit Date | 2022-02-02 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2022-12-15 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003382 |
---|---|
Analysis type | MS |
Chromatography type | HILIC |
Chromatography system | Thermo Vanquish |
Column | Waters Acquity UPLC BEH amide,(150 x 2.1mm,1.7um) |
MS Type | ESI |
MS instrument type | Orbitrap |
MS instrument name | Thermo Q Exactive HF hybrid Orbitrap |
Ion Mode | POSITIVE |
Units | peak height |
Chromatography:
Chromatography ID: | CH002500 |
Chromatography Summary: | Data acquisition : 3 µL sample aliquots were injected on a Waters Acquity UPLC BEH Amide column (150 mm length × 2.1 mm id; 1.7 μm particle size) maintained at 45°C. A Waters Acquity VanGuard BEH Amide pre-column (5 mm × 2.1 mm id; 1.7 μm particle size) was used as guard column. Mobile phase A was 100% LC-MS grade water with 10 mM ammonium formate and 0.125% formic acid and mobile phase B was 95:5 v/v acetonitrile:water with 10 mM ammonium formate and 0.125% formic acid. Gradient was started at 100% (B) for 2 min, 70% (B) at 7.7 min, 40% (B) at 9.5 min, 30% (B) at 10.25 min, 100% (B) at 12.75 min and isocratic until 16.75 min. The column flow was 0.4 mL/min. Vanquish UHPLC system (ThermoFisher Scientific) was used. |
Instrument Name: | Thermo Vanquish |
Column Name: | Waters Acquity UPLC BEH amide,(150 x 2.1mm,1.7um) |
Flow Gradient: | Gradient was started at 100% (B) for 2 min, 70% (B) at 7.7 min, 40% (B) at 9.5 min, 30% (B) at 10.25 min, 100% (B) at 12.75 min and isocratic until 16.75 min. |
Flow Rate: | 0.4 mL/min |
Solvent A: | 100% water; 0.125% formic acid; 10 mM ammonium formate |
Solvent B: | 95% acetonitrile/5% water 0.125% formic acid; 10 mM ammonium formate |
Chromatography Type: | HILIC |