Summary of Study ST002511
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001621. The data can be accessed directly via it's Project DOI: 10.21228/M85M6X This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002511 |
Study Title | Enhanced niche colonization and competition during bacterial adaptation to a fungus |
Study Type | Fungal / bacterial interaction |
Study Summary | Enhanced niche 1 colonization and competition during bacterial adaptation to a fungus |
Institute | Netherlands Institute of Ecology |
Department | Microbial Ecology |
Last Name | Tyc |
First Name | Olaf |
Address | Droevendaalsesteeg 10, 6708 PB Wageningen, The Netherlands |
Olaf.Tyc@kgu.de | |
Phone | +496963018046 |
Submit Date | 2023-03-16 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzML |
Analysis Type Detail | GC-MS |
Release Date | 2023-04-04 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004135 |
---|---|
Analysis type | MS |
Chromatography type | GC |
Chromatography system | Agilent 7890B |
Column | Restek Rtx-5Sil MS (30m x 0.25mm, 0.25um) |
MS Type | EI |
MS instrument type | QTOF |
MS instrument name | Agilent 7200 QTOF |
Ion Mode | POSITIVE |
Units | m/z |
Chromatography:
Chromatography ID: | CH003063 |
Chromatography Summary: | The volatiles were desorbed from the traps using an desorption unit (Unity TD-100, Markes International Ltd., Llantrisant, UK) at 210 °C for 12 min (He flow 50 mL/min) and trapped on a cold trap at -10 °C. The volatiles were introduced into the GC-Q-TOF (model Agilent 7890B GC and the Agilent 7200A QTOF, Santa Clara, USA) by heating the cold trap for 12 min to 250 °C. The used split ratio was 1:10 and the used column was a 30 × 0.25 mm ID RXI-5MS, film thickness 0.25 µm (Restek 13424-6850, Bellefonte, PA, USA). Temperature program was as follows: 39 °C for 2 min, from 39 °C to 95 °C at 3.5 °C/min, then to 165 °C at 4 °C/min, to 280 °C at 15 °C/min and finally to 320 °C at 30 °C/min, hold 7 min. The volatile organic compounds were ionized in EI mode at eV and mass spectra were acquired in full-scan-mode (30–400 U @ 5 scans/s). Mass-spectra were extracted with MassHunter Qualitative Analysis Software V B.06.00 Build 6.0.633.0 (Agilent Technologies, Santa Clara, USA). |
Instrument Name: | Agilent 7890B |
Column Name: | Restek Rtx-5Sil MS (30m x 0.25mm, 0.25um) |
Column Temperature: | 280°C |
Flow Gradient: | - |
Flow Rate: | 50 mL/min |
Solvent A: | - |
Solvent B: | - |
Chromatography Type: | GC |