Summary of Study ST001942

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001230. The data can be accessed directly via it's Project DOI: 10.21228/M8QH6V This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001942
Study TitleLipidomics of esophageal adenocarcinoma
Study SummaryLipidomics of esophageal adenocarcinoma
Institute
QIMR Berghofer Medical Research Institute
Last NameMolendijk
First NameJeffrey
AddressBuilding 181, Parkville VIC 3010 Australia
Emailjeff.molendijk@unimelb.edu.au
Phone0000000000
Submit Date2021-08-22
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2021-11-19
Release Version1
Jeffrey Molendijk Jeffrey Molendijk
https://dx.doi.org/10.21228/M8QH6V
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003182 AN003183 AN003184 AN003185 AN003186
Analysis type MS MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC HILIC
Chromatography system Agilent 6550 Agilent 6550 Agilent 6550 Agilent 6550 Agilent 6550
Column Agilent ZORBAX RRHD Eclipse Plus C18 (50 x 2.1mm,1.8um,95Å) Agilent ZORBAX RRHD Eclipse Plus C18 (50 x 2.1mm,1.8um,95Å) Agilent HILIC Plus RRHD (100 x 2.1mm,1.8um) Agilent HILIC Plus RRHD (100 x 2.1mm,1.8um) Agilent HILIC Plus RRHD (100 x 2.1mm,1.8um)
MS Type ESI ESI ESI ESI ESI
MS instrument type QTOF QTOF Triple quadrupole Triple quadrupole Triple quadrupole
MS instrument name Agilent 6550 QTOF Agilent 6550 QTOF Agilent 6490A QQQ Agilent 6490A QQQ Agilent 6490A QQQ
Ion Mode POSITIVE NEGATIVE POSITIVE POSITIVE NEGATIVE
Units m/z_RT m/z_RT counts counts counts

MS:

MS ID:MS002960
Analysis ID:AN003182
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Agilent Masshunter
Ion Mode:POSITIVE
  
MS ID:MS002961
Analysis ID:AN003183
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Agilent Masshunter
Ion Mode:NEGATIVE
  
MS ID:MS002962
Analysis ID:AN003184
Instrument Name:Agilent 6490A QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Method F1
Ion Mode:POSITIVE
  
MS ID:MS002963
Analysis ID:AN003185
Instrument Name:Agilent 6490A QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Method F2
Ion Mode:POSITIVE
  
MS ID:MS002964
Analysis ID:AN003186
Instrument Name:Agilent 6490A QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Method A1
Ion Mode:NEGATIVE