Summary of Study ST002817

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001748. The data can be accessed directly via it's Project DOI: 10.21228/M8RQ7M This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002817
Study TitleInvestigation of metabolism in hypertrophic cardiomyopathy - Lipidomics
Study SummaryWe propose the use of targeted metabolomics to define the metabolic and molecular pathways altered in 2 mouse models (R92W-TnT and R403Q-MHC) of hypertrophic cardiomyopathy (HCM) that span the spectrum of human disease (heart failure and sudden death), with the goal of identifying treatment targets. Parallel targeted metabolomics studies will be performed in heart tissue and plasma at rest and following inotrope stimulation. Since energy compromise is expected to be most marked when the heart is subject to increased workload, as is the case during high-intensity exercise or inotropic stimulation, we propose metabolomics studies in heart tissue and plasma, at rest and following inotrope stimulation. We anticipate that the results of these studies will allow us to move forward with further investigations into specific metabolites of interest as biomarkers, to be tested in HCM patients in future studies.
Institute
University of California, San Francisco
DepartmentHypertrophic Cardiomyopathy Center of Excellence
LaboratoryUCSF Smith Cardiovascular Research Building
Last NameAbraham
First NameMaria Roselle
Address555 Mission Bay Boulevard South, San Francisco, CA 94158
EmailRoselle.Abraham@ucsf.edu
Phone415-502-3911
Submit Date2023-07-27
Num Groups2 groups of 2 (i.e., mutant vs control of two mouse models of HCM (R402Q-MyHC, R92W-TnT)
Total Subjects32
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2023-09-06
Release Version1
Maria Roselle Abraham Maria Roselle Abraham
https://dx.doi.org/10.21228/M8RQ7M
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004584 AN004585 AN004586
Analysis type MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase
Chromatography system Agilent 1290 Agilent 1290 Waters Acquity
Column Waters ACQUITY UPLC CSH C18 (100 x 1mm,1.7um) Waters ACQUITY UPLC CSH C18 (100 x 1mm,1.7um) Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI ESI
MS instrument type QTOF QTOF Orbitrap
MS instrument name Agilent 6530 QTOF Agilent 6550 QTOF Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE
Units peak heights peak heights raw area counts rescaled to set the median equal to 1

MS:

MS ID:MS004330
Analysis ID:AN004584
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700 in positive (Agilent 6530, equipped with a JetStreamSource) and negative (Agilent 6550, equipped with a dual JetStream Source) modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 325°C, Gas Flow 8 l/min, Nebulizer 35 psig, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 120V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 2 scans per second. In negative ion mode, Gas Temp 200°C, Gas Flow 14 l/min, Fragmentor 175V, with the other parameters identical to positive ion mode. For the 6530 QTOF, a reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction. For the 6550, the reference solution is introduced via a dual spray ESI, with the same ions and continuous mass correction
Ion Mode:POSITIVE
  
MS ID:MS004331
Analysis ID:AN004585
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700 in positive (Agilent 6530, equipped with a JetStreamSource) and negative (Agilent 6550, equipped with a dual JetStream Source) modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 325°C, Gas Flow 8 l/min, Nebulizer 35 psig, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 120V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 2 scans per second. In negative ion mode, Gas Temp 200°C, Gas Flow 14 l/min, Fragmentor 175V, with the other parameters identical to positive ion mode. For the 6530 QTOF, a reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction. For the 6550, the reference solution is introduced via a dual spray ESI, with the same ions and continuous mass correction
Ion Mode:NEGATIVE
  
MS ID:MS004332
Analysis ID:AN004586
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Pos early)
Ion Mode:POSITIVE