Summary of Study ST002918

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001799. The data can be accessed directly via it's Project DOI: 10.21228/M85M79 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002918
Study TitleMetabolic Profiling in mouse Infected with Vibrio parahaemolyticus
Study SummaryMice were subject to intraperitoneal (i.p.) injection with the V. parahaemolyticus, and control mice were injected with saline. Data were collected and analyzed using unsupervised hierarchical clustering. In general, the abundance of metabolites increased more often than it decreased in animals with higher resistance to infection. Load weight analysis of biological pathways suggested that alanine, aspartate, glutamate metabolism could play roles in the capacity of mice to survive infection with V. parahaemolyticus.
Institute
Sun Yat-sen University
Last Namejiang
First Nameming
AddressNo. 135, Xingang Xi Road, Guangzhou, 510275, P. R. China
Emailjiangm28@mail.sysu.edu.cn
Phone13434283781
Submit Date2023-09-16
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailGC-MS
Release Date2023-10-05
Release Version1
ming jiang ming jiang
https://dx.doi.org/10.21228/M85M79
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004788
Analysis type MS
Chromatography type GC
Chromatography system Thermo Scientific Trace GC Ultra with DSQ II GC/MS
Column Agilent DB5-MS (30m x 0.25mm, 0.25um)
MS Type EI
MS instrument type Triple quadrupole
MS instrument name Thermo Scientific Trace GC Ultra with DSQ II GC/MS
Ion Mode POSITIVE
Units Peak area

MS:

MS ID:MS004534
Analysis ID:AN004788
Instrument Name:Thermo Scientific Trace GC Ultra with DSQ II GC/MS
Instrument Type:Triple quadrupole
MS Type:EI
MS Comments:samples was derivatized and then used to firstly protect carbonyl moieties through methoximation, through a 90 min 37 ℃ reaction with 40 μL of 20 mg/mL methoxyamine hydrochloride (Sigma-Aldrich) in pyridine, followed by derivatization of acidic protons through a 30 min 37 0C reaction with the addition of 80 μL N-methyl-N-trimethylsilyltrifluoroace-tamide (MSTFA, Sigma-Aldrich). The derivatized sample of 1 μL was injected into a 30m × 250 μm i.d. × 0.25 μm DBS-MS column using splitless injection and analysis was carried out by Trace DSQ II (Thermo Scientific). The initial temperature of the GC oven was held at 85 0C for 5 min followed by an increase to 330 0C at a rate of 15 0C min-1 then held for 5 min. Helium was used as carrier gas and flow was kept constant at 1 mL min-1. The MS was operated in a range of 50-600 m/z.
Ion Mode:POSITIVE
  logo