Summary of Study ST002997

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001867. The data can be accessed directly via it's Project DOI: 10.21228/M8CX3R This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002997
Study TitleMetabolomic analysis reveal mechanisms of Shenzao dripping pill against myocardial ischemia
Study TypeMetabolomic analysis on serum samples of SZDP against MI
Study SummaryThis study employed the advanced Ultra-high performance liquid chromatography-quadruple-Exactive Orbitrap mass spectrometry technology to detect biomarkers related to myocardial ischemia in rats. Additionally, it aimed to investigate the effect of the Shenzao dripping pill on rectifying metabolic disorders and preserving the metabolites in dynamic balance during myocardial ischemia, analyze potential metabolic pathways, and elucidate the mechanism of action of SZDP through the lens of metabolomics.
Institute
Guangdong Pharmaceutical University
DepartmentEngineering & Technology Research Center for Chinese Materia Medica Quality of the Universities of Guangdong Province
LaboratoryKey Laboratory of Digital Quality Evaluation of Chinese Materia Medica of State Administration of Traditional Chinese Medicine
Last NameKuang
First NameJiehui
AddressWaihuan East Road, 280, Guangzhou, Guangdong, 510006, China
Emailkuang_jieh@163.com
Phone(020)-222-3333
Submit Date2023-12-04
Raw Data AvailableYes
Raw Data File Type(s)mzML, raw(Thermo)
Analysis Type DetailLC-MS
Release Date2023-12-21
Release Version1
Jiehui Kuang Jiehui Kuang
https://dx.doi.org/10.21228/M8CX3R
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004922 AN004923
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Peak area Peak area

MS:

MS ID:MS004665
Analysis ID:AN004922
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Mass spectrometry was set to positive and negative ion switching mode using an electrospray ionization source operated at 350 °C. The specific MS conditions were established: the sheath gas flow rate was 55 arb. Units; the auxiliary gas flow rate was 15 arb. Units with a temperature of 200 °C; the electrospray voltage was 3.5 kV in positive ion mode and -3.8 kV in negative ion mode.
Ion Mode:POSITIVE
  
MS ID:MS004666
Analysis ID:AN004923
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Mass spectrometry was set to positive and negative ion switching mode using an electrospray ionization source operated at 350 °C. The specific MS conditions were established: the sheath gas flow rate was 55 arb. Units; the auxiliary gas flow rate was 15 arb. Units with a temperature of 200 °C; the electrospray voltage was 3.5 kV in positive ion mode and -3.8 kV in negative ion mode.
Ion Mode:NEGATIVE
  logo