Summary of Study ST002344

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001502. The data can be accessed directly via it's Project DOI: 10.21228/M8JD81 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002344
Study TitleThe impact of dietary serine/glycine restriction and myriocin treatment on hepatic sphingolipid diversity during prolonged high fat diet feeding.
Study SummaryWe wanted to determine the impact of dietary serine/glycine restriction on hepatic sphingolipidome.
Institute
Salk Institute for Biological Studies
DepartmentMolecular and Cell Biology Laboratory
LaboratoryMetallo Lab
Last NameHandzlik
First NameMichal
Address10010 N Torrey Pines Rd, La Jolla, California, 92037, USA
Emailmhandzlik@salk.edu
Phone2069601945
Submit Date2022-11-11
Num GroupsLFD, -SG LFD, HFD, -SG HFD, LFD+Veh, HFD+Veh, -SG HFD+Veh, -SG HFD+Myr
Total Subjects80
Num Males80
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2024-01-01
Release Version1
Michal Handzlik Michal Handzlik
https://dx.doi.org/10.21228/M8JD81
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003828
Analysis type MS
Chromatography type Reversed phase
Chromatography system 6460C
Column Peeke Scientific Spectra 3um C8SR (150 x 3mm)
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name Agilent 6460 QQQ
Ion Mode POSITIVE
Units normalized ion count/mg protein

Chromatography:

Chromatography ID:CH002833
Chromatography Summary:The gradient elution program consisted of the following profile: 0 min, 82% B; 3 min, 82% B; 4 min, 90% B, 18 min, 99% B; 25 min, 99%, 27 min, 82% B, 30 min, 82% B.
Instrument Name:6460C
Column Name:Peeke Scientific Spectra 3um C8SR (150 x 3mm)
Column Temperature:40
Flow Rate:0.5 ml/min
Solvent A:100% water; 0.2% formic acid; 2 mM ammonium formate
Solvent B:100% methanol; 0.2% formic acid; 1 mM ammonium formate
Chromatography Type:Reversed phase