Summary of Study ST003044

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001875. The data can be accessed directly via it's Project DOI: 10.21228/M8BX4T This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003044
Study TitleA High-Fat Eucaloric Diet Induces Reprometabolic Syndrome of Obesity in Normal Weight Women - lipidomics
Study SummaryLipidomics analysis was performed on plasma from human female subjects before, during, and after a high fat diet.
Institute
University of Colorado Denver
Last NameHaines
First NameJulie
Address12801 E 17th Ave, Room 1303, Aurora, Colorado, 80045, USA
Emailjulie.haines@cuanschutz.edu
Phone3037243339
Submit Date2023-12-15
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-02-05
Release Version1
Julie Haines Julie Haines
https://dx.doi.org/10.21228/M8BX4T
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004993 AN004994
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (30 x 2.1mm,1.7um) Phenomenex Kinetex C18 (30 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE POSITIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH003772
Chromatography Summary:Negative C18
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (30 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:0-3 min 10-95% B at 0.3 mL/min, 3-4.2 min hold at 95% B at 0.3 mL/min, 4.2-4.3 min drop to 10% B at 0.45 mL/min, 4.3-4.9 min hold at 10%B while lowering flow rate to 0.4 mL/min, 4.9-5 min hold at 10%B while lowering flow rate to 0.3 mL/min.
Flow Rate:0.3-0.4 ml/min
Sample Injection:10 uL
Solvent A:75% water/25% acetonitrile; 5 mM ammonium acetate
Solvent B:90% isopropanol/10% acetonitrile; 5 mM ammonium acetate
Chromatography Type:Reversed phase
  
Chromatography ID:CH003773
Chromatography Summary:Positive C18
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (30 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:0-3 min 30-100% B at 0.3 mL/min, 3-4.2 min hold at 100% B at 0.3 mL/min, 4.2-4.3 min 100-30% B at 0.4 mL/min, 4.3-4.9 min hold at 30%B and 0.4 mL/min, 4.9-5 min hold at 30%B while lowering flow rate to 0.3 mL/min
Flow Rate:0.3-0.4 ml/min
Sample Injection:10 uL
Solvent A:75% water/25% acetonitrile; 5 mM ammonium acetate
Solvent B:90% isopropanol/10% acetonitrile; 5 mM ammonium acetate
Chromatography Type:Reversed phase