Summary of Study ST001096

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000733. The data can be accessed directly via it's Project DOI: 10.21228/M8XM40 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001096
Study TitleArabidopsis thaliana 25 accessions
Study SummaryWaters Raw data can be downloaded for shoot- and root parts of Arabidopsis thaliana accessions.
Institute
RIKEN
DepartmentCenter for Sustainable Resource Science
LaboratoryMetabolome Informatics Research Team
Last NameTsugawa
First NameHiroshi
Address1-7-22 Suehiro-cho, Tsurumi-ku
Emailhiroshi.tsugawa@riken.jp
Phone+81-45-503-9618
Submit Date2018-11-14
Raw Data AvailableYes
Raw Data File Type(s)raw(Waters)
Analysis Type DetailLC-MS
Release Date2018-12-11
Release Version1
Hiroshi Tsugawa Hiroshi Tsugawa
https://dx.doi.org/10.21228/M8XM40
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001783 AN001784
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Waters Acquity Waters Acquity
Column Waters Acquity BEH C18 (100 x 2.1mm,1.7um) Waters Acquity BEH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Waters Synapt G2 S QTOF Waters Synapt G2 S QTOF
Ion Mode POSITIVE NEGATIVE
Units Peak intensity Peak intensity

MS:

MS ID:MS001647
Analysis ID:AN001783
Instrument Name:Waters Synapt G2 S QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:POSITIVE
Capillary Voltage:+3.00 kV
Collision Energy:6 V
Source Temperature:120
Desolvation Gas Flow:800 l/hr
Desolvation Temperature:450 degree C
Scan Range Moverz:50 - 1500
  
MS ID:MS001648
Analysis ID:AN001784
Instrument Name:Waters Synapt G2 S QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:NEGATIVE
Capillary Voltage:-2.75 kV
Collision Energy:6 V
Source Temperature:120
Desolvation Gas Flow:800 l/hr
Desolvation Temperature:450 degree C
Scan Range Moverz:50 - 1500
  logo