Summary of Study ST001106

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000740. The data can be accessed directly via it's Project DOI: 10.21228/M81D57 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001106
Study TitleLipidomics of Newborn Heart Tissue Exposed to Excess Maternal Cortisol in Late Gestation (part-1)
Study SummaryCardiac tissue from newborn hearts from animals exposed to excess maternal cortisol in late gestation and untreated was compared via MS lipidomic analysis
Institute
University of Florida
DepartmentBiochemsitry & Molecular Biology
Last NameWalejko
First NameJacquelyn
AddressR3-226 Academic Research Building, Department of Biochemistry and Molecular Biology, PO Box 100245, Gainesville, FL 32610-0245
Emailjwalejko@ufl.edu
Phonena
Submit Date2018-11-30
Num Groups2
Total Subjects12
Raw Data AvailableYes
Raw Data File Type(s)fid
Analysis Type DetailLC-MS
Release Date2019-03-06
Release Version1
Jacquelyn Walejko Jacquelyn Walejko
https://dx.doi.org/10.21228/M81D57
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001799 AN001800
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters Acquity BEH C18 (50 x 2.1mm,1.7um) Waters Acquity BEH C18 (50 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Relative peak area Relative peak area

MS:

MS ID:MS001660
Analysis ID:AN001799
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
Ion Mode:POSITIVE
Capillary Temperature:250C
Ion Spray Voltage:1500
Ionization:Heated electrospray
Resolution Setting:70,000
Scanning Range:200-2200 m/z
  
MS ID:MS001661
Analysis ID:AN001800
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
Ion Mode:NEGATIVE
Capillary Temperature:250C
Ion Spray Voltage:1500
Ionization:Heated electrospray
Resolution Setting:70,000
Scanning Range:200-2200 m/z
  logo