Summary of Study ST003027

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001876. The data can be accessed directly via it's Project DOI: 10.21228/M87426 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003027
Study TitleNMR- and MS-based omics reveal characteristic metabolome atlas and optimize biofluid earlydiagnostic biomarkers for esophageal squamous cell carcinoma (part-Ⅳ)
Study SummaryMetabolic changes precede malignant histology. However, it remains unclear whether detectable characteristic metabolome exists in esophageal squamous cell carcinoma (ESCC) tissues and biofluids for early diagnosis. We conducted NMR- and MS-based metabolomics on 1,153 matched ESCC tissues, normal mucosae, pre- and one-week post-operative sera and urines from 560 participants across three hospitals, with machine learning, logistic regression and WGCNA. Aberrations in 'alanine, aspartate and glutamate metabolism' proved to be prevalent throughout the ESCC evolution, and were reflected in 16 serum and 10 urine metabolic signatures that were consistently identified by NMR and MS in both discovery and validation sets. NMR-based simplified panels of any five serum or urine metabolites outperformed clinical serological tumor markers (AUC = 0.984 and 0.930, respectively), and were effective in distinguishing early-stage ESCC in test set (serum accuracy = 0.994, urine accuracy = 0.879). Collectively, NMR-based biofluid screening can reveal characteristic metabolic events of ESCC and be feasible for early detection (ChiCTR2300073613).
Institute
Radiology Department, Second Affiliated Hospital, Shantou University Medical College
Last NameLin
First NameYan
AddressNo. 69, Dongxia North Road, Shantou, Guangdong, China
Email994809889@qq.com
Phone+86 18823992148
Submit Date2023-12-16
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailGC/LC-MS
Release Date2024-02-08
Release Version1
Yan Lin Yan Lin
https://dx.doi.org/10.21228/M87426
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004962 AN004963
Analysis type MS MS
Chromatography type Normal phase Reversed phase
Chromatography system Waters Acquity H-Class Waters Acquity H-Class
Column Waters ACQUITY UPLC BEH HILIC (150 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH HILIC (150 x 2.1mm,1.7um)
MS Type EI ESI
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name ABI Sciex 6500 QTrap ABI Sciex 6500 QTrap
Ion Mode POSITIVE NEGATIVE
Units m/z m/z

MS:

MS ID:MS004702
Analysis ID:AN004962
Instrument Name:ABI Sciex 6500 QTrap
Instrument Type:Triple quadrupole
MS Type:EI
MS Comments:All the MS data acquisition and quantitative analysis of target compounds in this project were completed by SCIEX Analyst Work Station Software (1.7.2) and BIOTREE Bio Bud (2.1.4). The final concentration CF (Final Concentration, μmol/L) was directly measured by the instrument. The concentration CC (Calculated Concentration, μmol/L) multiplied by the dilute release factor page 6 / 11 Dil (Dilution Factor), in μmol/L. The target metabolite concentration CM (Metabolite Concentration, nmol/g) in the sample is equal to the final measured concentration CF times the final sample volume VF (Volume, μL) and the concentration factor CF of the sample during the pretreatment process, divided by the sample mass MS (Weight, mg), in nmol/g. NA indicated that no target metabolites were detected in the sample.
Ion Mode:POSITIVE
  
MS ID:MS004703
Analysis ID:AN004963
Instrument Name:ABI Sciex 6500 QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:All the MS data acquisition and quantitative analysis of target compounds in this project were completed by SCIEX Analyst Work Station Software (1.7.2) and BIOTREE Bio Bud (2.1.4). The final concentration CF (Final Concentration, μmol/L) was directly measured by the instrument. The concentration CC (Calculated Concentration, μmol/L) multiplied by the dilute release factor page 6 / 11 Dil (Dilution Factor), in μmol/L. The target metabolite concentration CM (Metabolite Concentration, nmol/g) in the sample is equal to the final measured concentration CF times the final sample volume VF (Volume, μL) and the concentration factor CF of the sample during the pretreatment process, divided by the sample mass MS (Weight, mg), in nmol/g. NA indicated that no target metabolites were detected in the sample.
Ion Mode:NEGATIVE