MB Sample ID: SA174465

Local Sample ID:146
Subject ID:SU001941
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003021 AN003022
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Vanquish Vanquish
Column Kinetex XB-C18 (150 x 2.1mm,1.7um) Kinetex XB-C18 (150 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE POSITIVE
Units peak area peak area

MS:

MS ID:MS002810
Analysis ID:AN003021
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The UHPLC system was coupled online with a QExactive mass spectrometer (Thermo, San Jose, CA, USA), scanning in Full MS mode (2 μscans) at 70,000 resolution from 60-900 m/z, with 4 kV spray voltage, 15 sheath gas and 5 auxiliary gas, operated in positive ion mode. Calibration was performed before each analysis using a positive calibration mix (Piercenet – Thermo Fisher, Rockford, IL, USA). Limits of detection (LOD) were characterized by determining the smallest injected amino acid amount required to provide a signal to noise (S/N) ratio greater than three using < 5 ppm error on the accurate intact mass. Based on a conservative definition for Limit of Quantitation (LOQ), these values were calculated to be three fold higher than determined LODs. MS data acquired from the QExactive was converted from .raw file format to.mzXML format using MassMatrix (Cleveland, OH, USA). Amino acid assignments were performed using MAVEN (Princeton, NJ, USA). The MAVEN software platform provides tools for peak picking, feature detection and metabolite assignment against the KEGG pathway database. Assignments were further confirmed using a process for chemical formula determination using isotopic patterns and accurate intact mass (Clasquin et al. 2012). Analyte retention times were confirmed by comparison with external standard retention times, as indicated above.
Ion Mode:NEGATIVE
  
MS ID:MS002811
Analysis ID:AN003022
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The UHPLC system was coupled online with a QExactive mass spectrometer (Thermo, San Jose, CA, USA), scanning in Full MS mode (2 μscans) at 70,000 resolution from 60-900 m/z, with 4 kV spray voltage, 15 sheath gas and 5 auxiliary gas, operated in positive ion mode. Calibration was performed before each analysis using a positive calibration mix (Piercenet – Thermo Fisher, Rockford, IL, USA). Limits of detection (LOD) were characterized by determining the smallest injected amino acid amount required to provide a signal to noise (S/N) ratio greater than three using < 5 ppm error on the accurate intact mass. Based on a conservative definition for Limit of Quantitation (LOQ), these values were calculated to be three fold higher than determined LODs. MS data acquired from the QExactive was converted from .raw file format to.mzXML format using MassMatrix (Cleveland, OH, USA). Amino acid assignments were performed using MAVEN (Princeton, NJ, USA). The MAVEN software platform provides tools for peak picking, feature detection and metabolite assignment against the KEGG pathway database. Assignments were further confirmed using a process for chemical formula determination using isotopic patterns and accurate intact mass (Clasquin et al. 2012). Analyte retention times were confirmed by comparison with external standard retention times, as indicated above.
Ion Mode:POSITIVE