Summary of Study ST000221

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000181. The data can be accessed directly via it's Project DOI: 10.21228/M8R30R This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000221
Study TitleNormal plasma cells,Low proliferation multiple myeloma and High proliferation multiple myeloma cells
Study Typedifferential metabolomics
Study SummaryCD138 sorted bone marrow plasma cell were obtained from a normal patient, a multiple myelow with slow proliferation and a multiple myelow with rapid proliferation.
Institute
Mayo Clinic
DepartmentHematology
Last NameGonsalves
First NameWilliam
EmailDasari.Surendra@mayo.edu
Submit Date2015-06-20
Num Groups1
Total Subjects1
Raw Data AvailableYes
Raw Data File Type(s)d
Uploaded File Size73 G
Analysis Type DetailLC-MS
Release Date2016-06-18
Release Version1
William Gonsalves William Gonsalves
https://dx.doi.org/10.21228/M8R30R
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000327 AN000328 AN000329 AN000330
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters high-strength silica (150 x 2.1mm,1.8um) Waters high-strength silica (150 x 2.1mm,1.8um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type TOF TOF TOF TOF
MS instrument name Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Peak area Peak area Peak area Peak area

Chromatography:

Chromatography ID:CH000246
Chromatography Summary:C18
Chromatography Comments:Metabolite separation was achieved using an Acquity UPLC system (Waters, Milford, MA) with both hydrophilic interaction chromatography (HILIC) (ethylene-bridged hybrid 2.1150 mm, 1.7 mm; Waters) and reversed-phase liquid chromatography C18 (RPLC) (high-strength silica 2.1150 mm, 1.8 m; Waters). For each column, the run time was 20 min at a flow rate of 400 L/min. Reverse-phase chromatography was performed using 99% solvent A (5 mmol/L NH4 acetate, 0.1% formic acid, and 1% acetonitrile) to 100% solvent B (95% acetonitrile with 0.1% formic acid). The gradient was 0 min, 0% B; 1 min, 0% B; 3 min, 5% B; 13.0 min, 100% B; 16 min, 100% B; 16.5 min, 0% B; and 20 min, 0% B. The hydrophilic interaction chromatography gradient was as follows: 0 min, 100% B; 1 min, 100% B; 5 min, 90% B; 13.0 min, 0% B; 16 min, 0% B; 16.5 min, 100% B; and 20 min, 100% B. The injection volume of each sample was 5 L and column was maintained at 50C.
Instrument Name:Waters Acquity
Column Name:Waters high-strength silica (150 x 2.1mm,1.8um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH000247
Chromatography Summary:HILIC
Chromatography Comments:Metabolite separation was achieved using an Acquity UPLC system (Waters, Milford, MA) with both hydrophilic interaction chromatography (HILIC) (ethylene-bridged hybrid 2.1150 mm, 1.7 mm; Waters) and reversed-phase liquid chromatography C18 (RPLC) (high-strength silica 2.1150 mm, 1.8 m; Waters). For each column, the run time was 20 min at a flow rate of 400 L/min. Reverse-phase chromatography was performed using 99% solvent A (5 mmol/L NH4 acetate, 0.1% formic acid, and 1% acetonitrile) to 100% solvent B (95% acetonitrile with 0.1% formic acid). The gradient was 0 min, 0% B; 1 min, 0% B; 3 min, 5% B; 13.0 min, 100% B; 16 min, 100% B; 16.5 min, 0% B; and 20 min, 0% B. The hydrophilic interaction chromatography gradient was as follows: 0 min, 100% B; 1 min, 100% B; 5 min, 90% B; 13.0 min, 0% B; 16 min, 0% B; 16.5 min, 100% B; and 20 min, 100% B. The injection volume of each sample was 5 L and column was maintained at 50C.
Instrument Name:Waters Acquity
Column Name:Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um)
Chromatography Type:HILIC
  logo