Summary of Study ST001253
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000840. The data can be accessed directly via it's Project DOI: 10.21228/M83Q36 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST001253 |
Study Title | Phenotyping Mouse blood metabolites in day and night in type 2 diabetes |
Study Type | time course in a 24hr period |
Study Summary | This experiment compares the metabolites in control db/m and diabetic db/db in day and night. |
Institute | Indiana University School of Medicine |
Department | Ophthalmology |
Laboratory | Maria Grant Laboratory |
Last Name | Beli |
First Name | Eleni |
Address | 97 Lisburn Road |
e.beli@qub.ac.uk | |
Phone | 5176144409 |
Submit Date | 2019-09-24 |
Num Groups | 4 |
Total Subjects | 15 |
Num Males | 15 |
Publications | Nutrients.2019. Beli E. Loss of diurnal oscillatory rhythms in gut microbiota correlates with changes in circulating metabolites in type 2 diabetic, db/db mice |
Raw Data Available | Yes |
Analysis Type Detail | LC-MS |
Release Date | 2019-10-11 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002079 | AN002080 | AN002081 | AN002082 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | Reversed phase | HILIC |
Chromatography system | Waters Acquity | Waters Acquity | Waters Acquity | Waters Acquity |
Column | Waters Acquity BEH C18 (100 x 2mm,1.7um) | Waters Acquity BEH C18 (100 x 2mm,1.7um) | Waters Acquity BEH C18 (100 x 2mm,1.7um) | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | POSITIVE | NEGATIVE | NEGATIVE |
Units | VolNormImp Area counts | VolNormImp Area counts | VolNormImp Area counts | VolNormImp Area counts |
Chromatography:
Chromatography ID: | CH001516 |
Chromatography Summary: | LC/MS Pos Early: Waters Acquity , Reversed phase, BEH C18 (100 X2mm, 1.7um), accidic, positive ion conditions |
Instrument Name: | Waters Acquity |
Column Name: | Waters Acquity BEH C18 (100 x 2mm,1.7um) |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH001517 |
Chromatography Summary: | LC/MS Pos Late: Waters Acquity , Reversed phase, BEH C18 (100 X2mm, 1.7um), acidic positive ion conditions |
Instrument Name: | Waters Acquity |
Column Name: | Waters Acquity BEH C18 (100 x 2mm,1.7um) |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH001518 |
Chromatography Summary: | LC/MS negative: Waters Acquity , Reversed phase, separate column BEH C18 (100 X2mm, 1.7um), basic negative ion optimized conditions |
Instrument Name: | Waters Acquity |
Column Name: | Waters Acquity BEH C18 (100 x 2mm,1.7um) |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH001519 |
Chromatography Summary: | LC/MS Polar: Instrument Waters Acquity , Reversed phase, Column: BEH Amide (150 X2mm, 1.7um), |
Instrument Name: | Waters Acquity |
Column Name: | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) |
Chromatography Type: | HILIC |