Summary of Study ST001909

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001203. The data can be accessed directly via it's Project DOI: 10.21228/M86Q68 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001909
Study TitleATF3 regulation of serine metabolism
Study Typestable isotope tracing
Study SummaryATF3 is a common stress sensor, and its expression can be induced by serine deprivation. The goal of this project is to determine whether ATF3 regulates serine biosynthesis. ATF3-wildtype and –knockout cells are cultured in complete or serine-free medium supplemented with 13C-6-glucose for 24 h for stable isotope tracing. The results show that ATF3 appears to promote serine biosynthesis.
Institute
Augusta University
Last NameYan
First NameChunhong
Address1410 Laney Walker Blvd, Augusta, GA, 30912, USA
Emailcyan@augusta.edu
Phone7067210099
Submit Date2021-08-11
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailGC-MS
Release Date2021-10-02
Release Version1
Chunhong Yan Chunhong Yan
https://dx.doi.org/10.21228/M86Q68
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003106
Analysis type MS
Chromatography type GC
Chromatography system Agilent 7890A
Column Restek Rtx-5Sil (30m x 0.25mm,0.25um)
MS Type EI
MS instrument type GC-TOF
MS instrument name Agilent 7890A
Ion Mode UNSPECIFIED
Units enrichment percentage

Chromatography:

Chromatography ID:CH002293
Chromatography Summary:Gas chromatography-Quadrupole-time of flight mass spectrometry (GC-Q-TOF MS) was used for Stable Isotope enrichment. Rtx-5Sil MS column (30m length, 0.25 mm i.d, 0.25 μM 95% dimethyl 5% diphenyl polysiloxane film) with an additional 10 m guard column was installed on Agilent 7890 GC (Agilent Technologies). 99.9999% pure Helium gas was used as a mobile phase with a flow rate of 1mL/min. GC temperature was held at 50°C for 1 min, ramped at 20°C/min to 330°C and then held for 5 min. Electron ionization at -70eV was employed on a Agilent 7250 Quadrupole time of flight mass spectrometer (Agilent Technologies) with ion source temperature at 250°C and detector voltage at 1850V. Mass spectra were acquired at an acquisition rate of 5 spectra/s, with a scan range of 85-900 Da.
Instrument Name:Agilent 7890A
Column Name:Restek Rtx-5Sil (30m x 0.25mm,0.25um)
Chromatography Type:GC
  logo