Summary of Study ST002510

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001620. The data can be accessed directly via it's Project DOI: 10.21228/M89B04 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002510
Study TitleStrain supernatants: Strain diversity of Eggerthella lenta metabolites in defined media
Study TypeUntargeted LC-MS
Study SummaryThis dataset contains untargeted metabolomics analysis of supernatants from stationary phase of a collection of 30 strains of Eggerthella lenta grown in defined EDM1 media.
Institute
University of California, San Francisco
Last NameNoecker
First NameCecilia
Address513 Parnassus Ave HSW1501, San Francisco, CA 94143
Emailcecilia.noecker@ucsf.edu
Phone415-502-3264
Submit Date2023-03-17
Raw Data AvailableYes
Raw Data File Type(s)mzML, raw(Thermo)
Analysis Type DetailLC-MS
Release Date2023-04-04
Release Version1
Cecilia Noecker Cecilia Noecker
https://dx.doi.org/10.21228/M89B04
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004133 AN004134
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish
Column Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units relative ion counts relative ion counts

Chromatography:

Chromatography ID:CH003062
Chromatography Summary:Samples, sterile media, pools, and blanks were promptly added to a Thermo Vanquish Autosampler at 4°C in a Vanquish UHPLC (Thermo Fisher Scientific, Waltham, MA). Chromatographic separation was performed using an ACQUITY Bridged Ethylene Hybrid (BEH) Amide column 2.1 x 150 mm, 1.7-micron particle size, (Waters Corp. Milford, MA), using chromatographic conditions published elsewhere (HILIC method described in the Supplementary Methods of doi.org/10.1038/s41586-021-03707-9).
Instrument Name:Thermo Vanquish
Column Name:Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um)
Column Temperature:40
Flow Gradient:The gradient profile was held at 100% B for 2 minutes, from 100% B to 70% B in 5 minutes, holding at 70% B for 0.7 minute, from 70% B to 40% B for 1.3 minutes, holding at 40% B for 0.5 minutes, from 40% B to 30% B for 0.75 minutes, before returning to 100% B for 2.5 minutes and holding at 100% B for 4 minutes.
Flow Rate:400 μL per minute
Solvent A:100% water; 0.125% formic acid; 10 mM ammonium formate, pH 3
Solvent B:95% acetonitrile/5% water; 0.125% formic acid; 10 mM ammonium formate
Chromatography Type:HILIC
  logo