This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001916. The data can be accessed directly via it's Project DOI: 10.21228/M82B0Z This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003076
Study TitleData-dependent and -independent acquisition lipidomics analysis reveals the tissue-dependent effect of metformin on lipid metabolism
Study SummaryFree fatty acids and polar metabolite analysis were conducted on six mouse tissues and plasma using HILIC chromatography coupled to a Q Exactive Plus mass spectrometer. This enabled a comprehensive assessment of fatty acid and metabolic changes induced by metformin across various tissues.
Institute
North Carolina State University
Last NameLiu
First NameXiaojing
Address128 Polk Hall, 120 W Broughton Dr.
Emailxliu68@ncsu.edu
Phone919.515.4387
Submit Date2024-02-07
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-03-01
Release Version1
Xiaojing Liu Xiaojing Liu
https://dx.doi.org/10.21228/M82B0Z
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005034
Analysis type MS
Chromatography type HILIC
Chromatography system Thermo Dionex Ultimate 3000
Column Waters Xbridge Amide (100 × 2.1 mm, 3.5 um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap
Ion Mode UNSPECIFIED
Units arbitrary unit

Chromatography:

Chromatography ID:CH003805
Chromatography Summary:A hydrophilic interaction chromatography method (HILIC) with an Xbridge amide column (100 x 2.1 mm i.d., 3.5 m; Waters) was used for compound separation at 25 °C. Mobile phase A: water with 5 mM ammonium acetate (pH 6.8), and mobile phase B: 100% acetonitrile. Linear gradient is: 0 min, 85% B; 1.5 min, 85% B; 5.5 min, 35% B; 6.9 min, 35% B; 10.5 min, 35% B; 10.6 min, 10% B; 12.5 min, 10% B; 13.5 min, 85% B; 17.9 min, 85% B; 18 min, 85% B; 20 min, 85% B. For Ultimate 3000 UHPLC, the flow rate is: 0-5.5 min, 0.15 ml/min; 6.9-10.5 min, 0.17 ml/min; 10.6-17.9 min, 0.3 ml/min; 18-20 min, 0.15 ml/min.
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Waters Xbridge Amide (100 × 2.1 mm, 3.5 um)
Column Temperature:25 °C
Flow Gradient:Linear gradient is: 0 min, 85% B; 1.5 min, 85% B; 5.5 min, 35% B; 6.9 min, 35% B; 10.5 min, 35% B; 10.6 min, 10% B; 12.5 min, 10% B; 13.5 min, 85% B; 17.9 min, 85% B; 18 min, 85% B; 20 min, 85% B.
Flow Rate:0.15 ml/min
Solvent A:100% water; 5 mM ammonium acetate
Solvent B:100% acetonitrile
Chromatography Type:HILIC