Summary of Study ST000414

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000323. The data can be accessed directly via it's Project DOI: 10.21228/M8ZS3N This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000414
Study TitleMetabolomics-based screening of the Malaria Box reveals both novel and established mechanisms of action
Study TypeDrug incubation
Study SummaryMeasuring the impact of MMV Malaria Box compounds on metabolism in Plasmodium falciparum-infected red blood cells
Institute
Monash Institute of Pharmaceutical Sciences
DepartmentDrug delivery, disposition and dynamics
LaboratoryCreek lab
Last NameCreek
First NameDarren
Address381 Royal Parade, Parkville, Melbourne, VIC3052, Australia
EmailDarren.Creek@monash.edu
PhoneN/A
Submit Date2016-06-16
Num Groups126
Total Subjects18
Study Comments524
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2017-07-10
Release Version1
Darren Creek Darren Creek
https://dx.doi.org/10.21228/M8ZS3N
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000655 AN000656
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS
Column ZIC-pHILIC (Merck Sequant) ZIC-pHILIC (Merck Sequant)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak height Peak height

MS:

MS ID:MS000581
Analysis ID:AN000655
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
Ion Mode:POSITIVE
Capillary Temperature:300°C
Capillary Voltage:+50V
Dry Gas Flow:20
Fragmentation Method:None
Ion Spray Voltage:3.5kV
Desolvation Gas Flow:50
Desolvation Temperature:150°C
Resolution Setting:35000
Scan Range Moverz:85- 1275 m/z
  
MS ID:MS000582
Analysis ID:AN000656
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
Ion Mode:NEGATIVE
Capillary Temperature:300°C
Capillary Voltage:-50V
Dry Gas Flow:20
Fragmentation Method:None
Ion Spray Voltage:3.5kV
Desolvation Gas Flow:50
Desolvation Temperature:150°C
Resolution Setting:35000
Scan Range Moverz:85- 1275 m/z