Summary of Study ST001851

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001168. The data can be accessed directly via it's Project DOI: 10.21228/M8QT2F This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001851
Study TitleQuantitative analysis of bile acids in fecal samples from centenarians, elderly and young subjects.
Study SummaryFecal samples from centenarians (>100 yo), elderly (85-89 yo) and young (21-55) subjects were analysed using LC-MS/MS. 48 bile acids were measured by targeted metabolomics.
Institute
Keio University School of Medicine
DepartmentDept of Microbiology and Immunology
Last NameKoji
First NameAtarashi
Address35 Shinanomachi, Shinjuku-ku, Tokyo, JAPAN
Emailkojiatarashi@keio.jp
Phone0353633769
Submit Date2021-05-24
Raw Data AvailableYes
Raw Data File Type(s)wiff
Analysis Type DetailLC-MS
Release Date2021-07-07
Release Version1
Atarashi Koji Atarashi Koji
https://dx.doi.org/10.21228/M8QT2F
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002999
Analysis type MS
Chromatography type Reversed phase
Chromatography system Exion LC
Column InertSustain C18
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name ABI Sciex Triple Quad 6500+
Ion Mode UNSPECIFIED
Units nM

MS:

MS ID:MS002788
Analysis ID:AN002999
Instrument Name:ABI Sciex Triple Quad 6500+
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:The following MS parameters were used for the positive ion MRM mode: ion spray voltage; 5,500 V, interface temperature; 500 °C, curtain gas; 30 psi, collision gas (nitrogen); 9 psi, nebulizing gas; 80 psi, and heater gas; 80 psi. For the negative ion MRM mode: ion spray voltage; -4,500 V, interface temperature; 500 °C, curtain gas; 30 psi, collision gas (nitrogen); 9 psi, nebulizing gas; 80 psi, and heater gas; 80 psi. Samples were obtained using Analyst software ver1.71 and analysed using SCIEX OS-MQ software ver1.7.0.36606.
Ion Mode:UNSPECIFIED
  logo